There shall be no projections into the required clear opening width lower than 34 inches (864 mm) above the finish floor or ground....
Search Results "Finished Grade"
Commonly Searched Documents
-
11B-404.2.3 Clear width
-
1133A.4.1, Item 4
Finished flooring shall be extended to the wall beneath the sink and work surface....
-
Height: ADA Standard Section 606.3
Section 606.3 covers the current ADA Standards for the height of lavatories and sinks.
-
11B-308.3.1 Unobstructed
approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1219 mm) maximum and the low side reach shall be 15 inches (381 mm) minimum above the finish...
-
Covered Multifamily Dwellings
The commenter stated that basements are generally designed with the top of the basement, including the basement entrance, above finished grade, and that basement space cannot be made accessible...
- EZConcept – Global Architectural Solutions
-
606.2 Clear Floor Space
floor extends under the cabinetry; and (c) the walls behind and surrounding the cabinetry are finished. 4....
-
606.2 Clear Floor Space
floor extends under the cabinetry; and (c) the walls behind and surrounding the cabinetry are finished. 4....
-
606.2 Clear Floor Space
floor extends under the cabinetry; and (c) the walls behind and surrounding the cabinetry are finished. 4....
-
11B-604.8.1.4 Toe clearance
At least one side partition shall provide a toe clearance of 9 inches (229 mm) minimum above the finish floor and 6 inches (152 mm) deep minimum beyond the compartment-side face of the partition...
-
11B-604.8.1.4 Toe clearance
At least one side partition shall provide a toe clearance of 9 inches (229 mm) minimum above the finish floor and 6 inches (152 mm) deep minimum beyond the compartment-side face of the partition...
-
11B-240.2.2 Elevated play components
Some play components that are attached to a composite play structure can be approached or exited at the ground level or above grade from a platform or deck....
-
904.4.1 Parallel Approach
A portion of the counter surface that is 36 inches (915 mm) long minimum and 36 inches (915 mm) high maximum above the finish floor shall be provided....
-
609.4 Position of Grab Bars
Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
904.4.1 Parallel Approach
A portion of the counter surface that is 36 inches (915 mm) long minimum and 36 inches (915 mm) high maximum above the finish floor shall be provided....
-
804.3.1 Clear Floor or Ground Space
the kitchen work surface provided that all of the following conditions are met: (a) the cabinetry can be removed without removal or replacement of the kitchen work surface; (b) the finish...
-
11B-804.3.1 Clear floor or ground space
kitchen work surface provided that all of the following conditions are met: (a) the cabinetry can be removed without removal or replacement of the kitchen work surface; (b) the finish...
-
609.4 Position of Grab Bars
Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
11B-804.3.1 Clear floor or ground space
the kitchen work surface provided that all of the following conditions are met: (a) the cabinetry can be removed without removal or replacement of the kitchen work surface; (b) the finish...
-
11B-804.3.1 Clear floor or ground space
work surface provided that all of the following conditions are met: (a) the cabinetry can be removed without removal or replacement of the kitchen work surface; (b) the finish...
-
14.4 Q. If a covered multifamily dwelling has a below grade common use parking garage, is there a requirement for a vertical clearance to allow vans to park?
A. This issue was addressed in the preamble to the Guidelines, but continues to be a frequently asked question. (See the preamble to the Guidelines under the discussion of Section...
-
Wheelchair Work Measurement Method
Work per meter values were also determined for the reference ramp grades and carpet/pad combinations....
-
Press Boxes [§206.2.7]
except where the aggregate area of all press boxes serving a playing field or assembly area is no more than 500 sq. ft. if press boxes are either: free-standing and elevated above grade...
-
602.4 Spout Height
Spout outlets shall be 36 inches (915 mm) maximum above the finish floor or ground....