Shelves shall be located 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor....
Search Results "Finished Grade"
Commonly Searched Documents
- 
    
  
  11B-603.4 Coat hooks, shelves and medicine cabinets
  
 - 
    
  
  4.4.1* General
  
Objects projecting from walls (for example, telephones) with their leading edges between 27 in and 80 in (685 mm and 2030 mm) above the finished floor shall protrude no more than 4 in (100...
 - 
    
  
  11B-611.4 Height
  
Top loading machines shall have the door to the laundry compartment located 36 inches (914 mm) maximum above the finish floor....
 - 
    
  
  611.4 Height
  
Top loading machines shall have the door to the laundry compartment located 36 inches (915 mm) maximum above the finish floor....
 - 
    
  
  Main Lobby
  
The 40 1/2" height of the main ticket counter exceeds the maximum allowable height of 36" above the finished floor. See Standards § 7.2(1). j....
 - 
    
  
  4.10.12(3)
  
All floor buttons shall be no higher than 54 in (1370 mm) above the finish floor for side approach and 48 in (1220 mm) for front approach....
 - 
    
  
  4.1.5 Slope
  
When the surface is not paved or is not elevated above the natural ground, grades not steeper than 1:33 (3 percent) shall be permitted where necessary for drainage....
 - 
    
  
  11B-904.4.1 Parallel approach
  
A portion of the counter surface that is 36 inches (914 mm) long minimum and 34 inches (864 mm) high maximum above the finish floor shall be provided....
 - 
    
  
  Getting In
  
Building entries must be flush with the grade of the outside access route and have a beveled doorsill that is not more than one-half inch high....
 - 
    
  
  Section 2. Ground floor
  
Where the first floor containing dwelling units in a building is above grade, all units on that floor must be served by a building entrance on an accessible route....
 - 
    
  
  611.4 Height
  
Top loading machines shall have the door to the laundry compartment located 36 inches (915 mm) maximum above the finish floor....
 - 
    
  
  Design of Shared Use Paths, Street Intersections, and Midblock Crossings
  
At-grade Intersection Design. 5. Design of Grade-separated Crossings. 6. Sidewalks and "Sidepath" Design Guidance. These sections are further detailed below. 1. ...
 - 
    
  
  11B-306.3.1 General
  
Space under an element between 9 inches (229 mm) and 27 inches (686 mm) above the finish floor or ground shall be considered knee clearance and shall comply with Section 11B-306.3....
 - 
    
  
  11B-306.3.1 General
  
Space under an element between 9 inches (229 mm) and 27 inches (686 mm) above the finish floor or ground shall be considered knee clearance and shall comply with Section 11B-306.3. ...
 - 
    
  
  11B-306.3.1 General
  
Space under an element between 9 inches (229 mm) and 27 inches (686 mm) above the finish floor or ground shall be considered knee clearance and shall comply with Section 11B-306.3....
 - 
    
  
  Scenario 3 – Disabilities in Remission
  
Doctors diagnosed Omar with cancer at the beginning of the summer break, between fourth grade and fifth grade....
 - 
    
  
  604.7 Dispensers
  
The outlet of the dispenser shall be 15 inches (380 mm) minimum and 48 inches (1220 mm) maximum above the finish floor and shall not be located behind grab bars....
 - 
    
  
  4.4.1* GENERAL
  
Objects projecting from walls (for example, telephones) with their leading edges between 27 in and 80 in (685 mm and 2030 mm) above the finished floor shall protrude no more than 4 in (100...
 - 
    
  
  604.7 Dispensers
  
The outlet of the dispenser shall be 15 inches (380 mm) minimum and 48 inches (1220 mm) maximum above the finish floor and shall not be located behind grab bars....
 - 
    
  
  Other international standards
  
Australian NATSPEC Reference Volume 1: Building Works, Concrete Finishes Section Three classes of surface finish based on using a straightedge method of testing: Class A...
 - 
    
  
  404.2.11 Vision Lights
  
or gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel located 43 inches (1090 mm) maximum above the finish...
 - 
    
  
  307.4 Vertical Clearance
  
The leading edge of such guardrail or barrier shall be located 27 inches (685 mm) maximum above the finish floor or ground....
 - 
    
  
  11B-809.9.3 Removable base cabinets
  