Signs shall comply with 703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one with visual,...
Search Results "Approach Enter Exit"
Commonly Searched Documents
-
703.1 General
-
703.4.2 Location
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side. Where a tactile sign is provided at double doors with one active leaf, the...
-
703.4.2 Location
703.4.2 Location. Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side. Where a tactile sign is provided at double doors with...
-
216.1 General
216.1 General. Signs shall be provided in accordance with 216 and shall comply with 703. EXCEPTIONS: 1. Building directories, menus, seat and row designations in assembly areas,...
-
703.1 General
703.1 General. Signs shall comply with 703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one...
-
703.5.6 Height from Finish Floor or Ground
703.5.6 Height from Finish Floor or Ground. Visual characters shall be 40 inches (1015 mm) minimum above the finish floor or ground. EXCEPTION: Visual characters indicating...
-
703.5.3 Style
703.5.3 Style. Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.
-
4.1.2(7) Building Signage
(7) Building Signage. Signs which designate permanent rooms and spaces shall comply with 4.30.1, 4.30.4, 4.30.5 and 4.30.6. Other signs which provide direction to, or information...
-
F216.1 General
Signs shall be provided in accordance with F216 and shall comply with 703.
-
4.1.1(7)
(7) All signs shall comply with 4.30. Elements and spaces of accessible facilities which shall be identified by the International Symbol of Accessibility are: (a) Parking spaces...
-
11B-703.1 General
11B-703.1 General. Signs shall comply with Section 11B-703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two...
-
11B-703.5.3 Style
11B-703.5.3 Style. Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.
-
11B-703.5.3 Style
Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.
-
11B-703.1 General
Signs shall comply with Section 11B-703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one...
-
B. The ADA Standards for Accessible Design
Rather, they are designed to provide a convenient degree of access for most people with disabilities to approach, enter, and use a facility. See H. R. Rep....
-
11B-904.2 Approach
Advisory 11B-904.2 Approach....
- Access Board: Tactile Sign Location
- Access Board: Tactile Sign Height
-
Entering Content in Corada WorkSpace
Entering Content in Corada WorkSpace...
-
Safety Considerations for Site Selection
Choose facilities that are protected by audible and visible fire alarms and a fire sprinkler system. The U.S. Fire Administration has a list of approved hotels and motels. It is...
-
A4.30.5 Finish and Contrast
An eggshell finish (11 to 19 degree gloss on 60 degree glossimeter) is recommended. Research indicates that signs are more legible for persons with low vision when characters...
-
4.30.5* Finish and Contrast
4.30.5* Finish and Contrast. The characters and background of signs shall be eggshell, matte, or other non-glare finish. Characters and symbols shall contrast with their background...
-
4.30.3* COLOR CONTRAST
Characters and symbols shall contrast with their background - either light characters on a dark background or dark characters on a light background.