EXCEPTION: Entry doors to acute care hospital bedrooms for in-patients shall be exempted from the requirement for space at the latch side of the door (see dimension “x” in Fig. 25) if the...
Search Results "Non-Occupiable Space"
-
4.13.6 Maneuvering Clearances at Doors
-
7.2(2)(iii)
counter, equivalent facilitation might consist of: (1) provision of a folding shelf attached to the main counter on which an individual with disabilities can write, and (2) use of the space...
-
Vertical Wheelchair Lifts
However, if a fixed seat is provided, the minimum space required for wheelchairs must still be provided. Folding or flip-down seats can be used....
-
Inventory Control Devices
When doors are automated, maneuvering space is not required....
-
F244.5.2 Routes to and Within Common Use and Public Use Areas
EXCEPTION: Outdoor recreation access routes shall not be required to connect camping units with mobility features and recreational vehicle dump stations where a pull-up space complying with...
-
4.2.6* SIDE REACH
If the clear floor space allows parallel approach by a person in a wheelchair, the maximum high side reach allowed shall be 54 in (1370 mm) and the low side reach shall be no less than 9...
-
Are closet doors and pantry doors required to comply?
cabinets and other storage elements not providing user passage do not have to comply with provisions for doors, but must meet requirements for storage (§811), including those for clear floor space...
-
TECHNICALLY INFEASIBLE
alteration of a load-bearing member that is an essential part of the structural frame, or because other existing physical or site constraints prohibit modification or addition of elements, spaces...
-
11B-703.1.1.2 Inspection
The inspection shall include, but not be limited to, verification that Braille dots and cells are properly spaced and the size, proportion and type of raised characters are in compliance...
-
TECHNICALLY INFEASIBLE
alteration of a load-bearing member that is an essential part of the structural frame, or because other existing physical or site constraints prohibit modification or addition of elements, spaces...
-
225.2 Storage
Where storage is provided in accessible spaces, at least one of each type shall comply with 811. Advisory 225.2 Storage....
- Rebuilding Together Monterey/Salinas - Monterey, CA
-
Entrances
All door openings must provide a minimum width of 32 inches and there must also be enough room for a person using a wheelchair to maneuver to open the door, including 18 inches of clear space...
-
Serving Counters
Lowered serving counter provides an accessible space to select and receive food items Notes on photo: Door under counter can be opened to provide required knee clearance when customers...
-
R204 Pedestrian Access Routes (Section-by-Section Analysis)
Pedestrian access routes in the public right-of-way are analogous to accessible routes on sites in that they connect to accessible elements, spaces, and facilities in the public right-of-way...
-
3. MAP YOUR COMMUNITY
that may serve as resources during an emergency: Social service organizations, faith-based organizations Active coalitions, civic or tenant associations Public spaces...
-
TABLE OF CONTENTS
202 Existing Buildings and Facilities 203 General Exceptions 204 Protruding Objects 205 Operable Parts 206 Accessible Routes 207 Accessible Means of Egress 208 Parking Spaces...
-
Issue 21: What additional education and training are needed for supervisors of employees with low vision?
Are you saying that the chief architect’s space where I work, which I consider not accessible at all because there is no contrast, is that not in compliance?...
-
III-1.2000 Public accommodations
. , inns, hotels, motels) (except for owner-occupied establishments renting fewer than six rooms); 2) Establishments serving food or drink (e.g. , restaurants and bars); 3) Places...
- Access 2 Independence (A2i) - Columbus, GA
-
TECHNICALLY INFEASIBLE
alteration of a load-bearing member that is an essential part of the structural frame, or because other existing physical or site constraints prohibit modification or addition of elements, spaces...
-
804.2 Clearance
EXCEPTION: Spaces that do not provide a cooktop or conventional range shall not be required to comply with 804.2. Advisory 804.2 Clearance....
-
11B-220.1.2 Two automatic teller machines or fare machines
are provided at a location, one shall comply with Sections 11B-707.2 through 11B-707.8 and one shall comply with Sections 11B-309 _|Operable Parts|_, 11B-707.2 _|Clear Floor or Ground Space...
-
F216.4.1 Exit Doors
An exit passageway is a horizontal exit component that is separated from the interior spaces of the building by fire-resistance-rated construction and that leads to the exit discharge or...