Additional factors affecting the ease with which the text can be distinguished from its background include shadows cast by lighting sources, surface glare, and the uniformity of the text...
Search Results "Fire-Building Surface"
-
703.6.2 Finish and Contrast
-
703.6.2 Finish and Contrast
Additional factors affecting the ease with which the text can be distinguished from its background include shadows cast by lighting sources, surface glare, and the uniformity of the text...
-
1132A.4, Item 3
Secondary exterior doors onto decks, patios, or balcony surfaces constructed of impervious materials (e.g., concrete, brick, flagstone) may have a maximum change in height from the interior...
-
407.2 Contrast (Section-by-Section Analysis)
407.2 Contrast (Section-by-Section Analysis) This section proposes that keys and controls, where provided, contrast visually from background surfaces....
-
5.3.6 Entrance
The entrance to the toilet shall be level with the surrounding surface....
-
4.9.4(2)
At the top, the extension shall be parallel with the floor or ground surface....
-
5.3.6 Entrance
The entrance to the toilet shall be level with the surrounding surface....
-
1016.6 Openings
Openings in the surface of outdoor recreation access routes shall not allow the passage of a sphere more than 1/2 inch (13 mm) in diameter. Advisory 1016.6 Openings....
-
Error/Omission: Landing areas where ramps change direction (e.g., switchbacks or 90° turns) are too small.
Result: Wheelchair users are unable to go up or down the ramp because there is not enough space to turn on a level surface. This makes the ramp unusable....
-
11B-703.7.2.7 Pedestrian traffic-control buttons
Control buttons shall be located no higher than 48 inches (1219 mm) above the ground surface adjacent to the pole....
-
1009.5.4 Transfer Steps
The surface of the bottom tread shall extend to a water depth of 18 inches (455 mm) minimum below the stationary water level. Advisory 1009.5.4 Transfer Steps....
-
403.5.1 Clear Width
Except as provided in 403.5.2 and 403.5.3, the clear width of walking surfaces shall be 36 inches (915 mm) minimum....
-
403.5.3 Passing Spaces
Passing spaces shall be either: a space 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum; or, an intersection of two walking surfaces providing a T-shaped space complying with...
-
703.6.2 Finish and Contrast
Additional factors affecting the ease with which the text can be distinguished from its background include shadows cast by lighting sources, surface glare, and the uniformity of the text...
-
Kurt Knight: Development of VA Standards
We don’t use it in other types of functions that don’t change as rapidly as a clinic building or a bed building....
-
PLATFORM
A raised area within a building used for worship, the presentation of music, plays or other entertainment; the head table for special guests; the raised area for lecturers and speakers;...
-
11B-802.1.5 Overlap
The term "circulation paths" used in 802.1.5 means aisle width required by applicable building or life safety codes for the specific assembly occupancy....
-
TECHNICALLY INFEASIBLE
An alteration of a building or a facility that has little likelihood of being accomplished because the existing structural conditions require the removal or alteration of a load-bearing...
-
Assembly Area
A building or facility, or portion thereof, used for the purpose of entertainment, educational or civic gatherings, or similar purposes....
-
F202.2.3 Toilet and Bathing Facilities
Where toilet facilities and bathing facilities are not provided in an addition but are provided in the existing building or facility to serve the addition, the toilet facilities and bathing...
-
BACKGROUND
The purpose of these code requirements is to ensure that barrier-free design is incorporated in all buildings, facilities, site work, additions, alterations, and structural repairs....
-
CAL Green requires x number of EVSE per xxx number of spaces - each on its own 40 amp circuit. Some dual EVSE are on a single 40 amp circuit and split the 40 amp. Does this mean that half of those plugs don't comply with the required number?
For additional information you may contact the Department of Housing and Community Development for infrastructure requirements at residential locations or the Building Standards Commission...
-
Furniture in Space with Clutter
This (slide 6) is a blowup of a plan from, like, a 1940s or ‘50s German office building....