Guest rooms required to provide communication features shall comply with 806.3. Advisory 806.3 Guest Rooms with Communication Features....
Search Results "Patient Room"
Commonly Searched Documents
-
806.3 Guest Rooms with Communication Features
-
806.3 Guest Rooms with Communication Features
Guest rooms required to provide communication features shall comply with 806.3. Advisory 806.3 Guest Rooms with Communication Features....
-
4.35.2 Clear Floor Space
A clear floor space allowing a person using a wheelchair to make a 180-degree turn shall be provided in every accessible dressing room entered through a swinging or sliding door....
-
5.9.1 Standing Supports Recommendation In Reference To Mammography Equipment
During discussion, there was general agreement that the real use of these supports is for positioning, and thus, not meant to support the full weight of the patient or to keep a patient...
-
224 Transient Lodging Guest Rooms
224 Transient Lodging Guest Rooms...
-
Transfer Supports Location and Configuration M301.3 and M302.3
Transfer Supports Location and Configuration M301.3 and M302.3 Location of the transfer supports shall be a minimum of 6 inches to a maximum of 19 inches from the top of the...
-
Gripping Surface Cross Section and Clearances M301, M302, and M305.2
Gripping Surface Cross Section and Clearances M301, M302, and M305.2 Gripping surface for transfer supports shall be free of sharp or abrasive elements and shall have rounded...
-
§ 35.151(b)(4)(i)(A)
(A) Mechanical rooms, boiler rooms, supply storage rooms, employee lounges or locker rooms, janitorial closets, entrances, and corridors are not areas containing a primary function. ...
-
§ 35.151(b)(4)(i)(A)
(A) Mechanical rooms, boiler rooms, supply storage rooms, employee lounges or locker rooms, janitorial closets, entrances, and corridors are not areas containing a primary function....
-
M301.2.3.1 End Transfer Surface
imaging equipment with bores shall be permitted to be 21 inches (535 mm) wide minimum but shall not be permitted to be less than the full width of the examination surface provided for the patient...
-
M301.2.3.2 Side Transfer Surface
imaging equipment with bores shall be permitted to be 21 inches (535 mm) wide minimum but shall not be permitted to be less than the full width of the examination surface provided for the patient...
-
11B-806.2 Guest rooms with mobility features
Guest rooms required to provide mobility features shall comply with Section 11B-806.2. [2010 ADAS] Advisory 806.2 Guest Rooms with Mobility Features. ...
-
11B-806.2 Guest rooms with mobility features
Guest rooms required to provide mobility features shall comply with Section 11B-806.2. [2010 ADAS] Advisory 806.2 Guest Rooms with Mobility Features....
-
11B-806.2 Guest rooms with mobility features
Guest rooms required to provide mobility features shall comply with Section 11B-806.2. Advisory 11B-806.2 Guest rooms with mobility features....
-
11B-206.7.6 Guest rooms and residential dwelling units
Platform lifts shall be permitted to connect levels within transient lodging guest rooms required to provide mobility features complying with Section 11B-806.2 or residential dwelling units...
-
11B-213.2.4 Multi-user all-gender toilet facilities
Where multi-user all-gender toilet facilities are provided, they shall comply with Section 11B-213.3.1.
-
5.4.3 Transfer Support Height for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.3 Transfer Support Height for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position. Transfer supports should be positioned 6 inches minimum and 19 inches maximum...
-
F241 Saunas and Steam Rooms
[See subsections ...]
-
241 Saunas and Steam Rooms
[See subsections ...]
-
11B-809.10.3 Powder rooms
Powder rooms shall be designed to comply with Sections 11B-809.7, 11B-809.8, 11B-809.10.5.2, 11B-809.10.6.4, 11B-809.10.7.3, and 11B-809.12....
-
§ 35.150(b)(2)(ii)(I) Saunas and steam rooms
(I) Saunas and steam rooms, sections 241 and 612....
-
M301.2.4 Unobstructed Transfer
Each transfer surface shall provide two unobstructed sides for patient transfer. EXCEPTIONS: 1....
-
Accessible Medical Equipment
Importance of Accessible Examination Tables, Chairs and Weight Scales http://www.hfcdihp.org/products Exam Room Selection for Accessible Examination Tables & Chairs PDF , Word...
-
5.5.1 Armrest Provision for M302
5.5.1 Armrest Provision for M302 Description: Diagnostic equipment used by patients in a seated position such as exam chairs typically have armrests....