Section 308.3.1 covers the current ADA Standards for unobstructed side reach.
Search Results "Mitigating Measures"
-
Unobstructed: ADA Standard Section 308.3.1
-
907.4.2.2 Height
The height of the manual fire alarm boxes shall be not less than 42 inches (1067 mm) and not more than 48 inches (1219 mm) measured vertically, from the floor level to the highest point...
-
907.4.2.2 Height
The height of the manual fire alarm boxes shall be not less than 42 inches (1067 mm) and not more than 48 inches (1219 mm) measured vertically, from the floor level to the highest point...
-
Opening Force [§404.2.9]
Latch bolts must be retracted and other devices that keep doors or gates closed must be disengaged prior to measuring the opening force....
-
1015.3 Height
Required guards shall not be less than 42 inches (1067 mm) high, measured vertically as follows: From the adjacent walking surfaces....
-
The Brewer Company, LLC
In addition, the AWM Project measured the rear compressed seat height of the wheeled mobility device with the user seated in it....
-
F. Cost and benefits of movie captioning and video description regulations
Are there any cost-sharing or cost-allocation agreements that help mitigate these costs for movie theater owners or operators? Is most or all of this expense a one-time fee?...
-
E102.8.2 TIA 1083
Telephone Terminal Equipment Handset Magnetic Measurement Procedures and Performance Requirements, (March 2007), IBR proposed for Section 410.4.2....
-
1014.2.1.2 Floor Height
The camp shelter floor at the entrance shall be 19 inches (485 mm) high maximum measured from the clear ground space....
-
§ 36.304(c) Priorities
A public accommodation is urged to take measures to comply with the barrier removal requirements of this section in accordance with the following order of priorities....
-
Sec.36.304(c) Priorities
A public accommodation is urged to take measures to comply with the barrier removal requirements of this section in accordance with the following order of priorities....
-
Technical Requirements
Are the specific numbers, conditions, and measurements that are required to be achieved (percent that must comply, dimensions, reach ranges, grades, trail width, etc.)....
-
1013.4 Height
This section requires tent platforms to be 19 inches high maximum measured from the clear ground space to the tent platform surface....
-
Technical Requirements
The specific numbers, conditions, and measurements that are required to be achieved (percent that must comply, dimensions, reach ranges, grades, trail width, etc.). ...
-
1014.2.1.2 Floor Height
The camp shelter floor at the entrance shall be 19 inches (485 mm) high maximum measured from the clear ground space....
-
1.6.17 Sterile Area.
A portion of an airport, specified in the airport security program, in which certain security measures specified in 49 CFR part 1542, Airport Security, are carried out....
-
604.4 Seats
The seat height of a water closet above the finish floor shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured to the top of the seat....
-
604.4 Seats
The seat height of a water closet above the finish floor shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured to the top of the seat....
-
604.4 Seats
The seat height of a water closet above the finish floor shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured to the top of the seat....
-
2. Referenced Documents
2.1 ASTM standards E867 Standard Terminology Relating to Vehicle-Pavement Systems E1364 Standard Test Method for Measuring Road Roughness by Static Level Method E1926 Standard...
-
Acknowledgments
Acknowledgments The development of objective surface measurement devices and objective surface testing was conducted with funding from the National Center for Medical Rehabilitation Research...
-
604.4 Seats
The seat height of a water closet above the finish floor shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured to the top of the seat....
-
11B-609.4 Position of grab bars
Grab bars shall be installed in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
I. Slip Resistant Surface—Aisles, Steps, Floor Areas Where People Walk, Floor Areas in Securement Locations, Lift Platforms, Ramps
While the dynamic coefficient of friction during walking varies in a complex and non-uniform way, the static coefficient of friction, which can be measured in several ways, provides a close...