Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units horizontal (5-percent slope), or a ramp, elevator or...
Search Results "Horizontal Projection"
-
1131A.2 Changes greater than ½ inch
-
1131A.2 Changes greater than ½ inch
Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units horizontal (5-percent slope), or a ramp, elevator or...
-
704.2.1 Types I and II construction
Projections from walls of Type I or II construction shall be of noncombustible materials or combustible materials as allowed by Sections 1406.3 and 1406.4....
- Bobrick ClassicSeries Surface-Mounted Soap Dispenser B-2112
-
505.10.3 Bottom Extension at Stairs
At the bottom of a stair flight, handrails shall extend at the slope of the stair flight for a horizontal distance at least equal to one tread depth beyond the last riser nosing....
-
T404.3 Ramps and Bridgeplates
Where the space between the floor of non-rail vehicles and a boarding platform is greater than 2 inches (51 mm) horizontally or 5/8 inch (16 mm) vertically when measured at 50 percent passenger...
-
4. Grab Bars
Does the toilet in each accessible guestroom bathroom have a horizontal grab bar along the adjacent side wall that is at least 42" long and mounted 33"-36" above the floor for stabilization...
-
1131A.1 Changes in level not exceeding ½ inch
When changes in level do occur, they shall be beveled with a slope no greater than 1 unit vertical in 2 units horizontal (50-percent slope)....
-
ACCESSIBLE MEANS OF EGRESS
A continuous and unobstructed way of egress travel from any point in a building or facility that provides an accessible route to an area of refuge, a horizontal exit, or a public way....
-
1131A.1 Changes in level not exceeding ½ inch
When changes in level do occur, they shall be beveled with a slope no greater than 1 unit vertical in 2 units horizontal (50-percent slope)....
-
EXHIBIT C Certification of ADA Compliance
I, [insert name], in my capacity as a Licensed Architect or Construction/Project Manager acting on behalf of QuikTrip Corporation pursuant to a certain Consent Decree executed by the parties...
-
SHOPPING CENTER (OR SHOPPING MALL)
on a common site, connected by a common pedestrian access route on, above or below the ground floor, that is either under common ownership or common control or developed either as one project...
-
68.50. Submission of Construction Documents
(d) An Architectural Barriers Project Registration form or Architectural Barriers Project Registration Confirmation Page must be submitted for each subject building or facility and submitted...
-
ACCESSIBLE MEANS OF EGRESS
A continuous and unobstructed way of egress travel from any point in a building or facility that provides an accessible route to an area of refuge, a horizontal exit, or a public way....
-
1007.6.2 Separation
Each area of refuge shall be separated from the remainder of the story by a smoke barrier complying with Section 709 or a horizontal exit complying with Section 1025....
-
5. Grab Bars
Does the accessible toilet in each accessible guestroom bathroom have a horizontal grab bar along the wall behind the toilet that is at least 36" long and mounted 33"-36" above the floor...
-
11B-505.10.2 Top extension at stairs
At the top of a stair flight, handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beginning directly above the first riser nosing....
-
Elevator Car Requirements [§407.4.2 – §407.4.5]
Elevator Car Requirements [§407.4.2 – §407.4.5] Other requirements for elevator cars include: compliant floor surfaces a maximum 1¼” horizontal clearance between car...
-
Areas of Refuge [IBC §1007.6 (2003), §1003.2.13.5 (2000)]
Horizontal exits can substitute for areas of refuge. Features of Areas of Refuge...
-
§ 38.113(d)(3) Exception
Where platform set-backs do not allow the horizontal gap or vertical alignment specified in paragraph (d) (1) or (2), platform or portable lifts complying with §38.125(b) of this part, or...
- SciFit Inclusive Fitness ISO7000R - Recumbent Bike
-
4.1.6(3)(d)(i)
(i) Where it is technically infeasible to comply with clear opening width requirements of 4.13.5, a projection of 5/8 in maximum will be permitted for the latch side stop....
-
Dispersion Requirements
Like the proposed rule, specifications are provided for horizontal (side to side) and vertical (front to back) dispersion....
-
704.9 Vertical separation of openings
exterior walls in adjacent stories shall be separated vertically to protect against fire spread on the exterior of the buildings where the openings are within 5 feet (1524 mm) of each other horizontally...