Where a forward approach is provided, the distance from the front edge of a counter within the telephone enclosure to the face of the telephone unit shall be 20 inches (510 mm) maximum....
Search Results "Shower Enclosure"
Commonly Searched Documents
-
Forward Approach: ADA Standard Section 704.2.1.2
-
11B-610.3 Shower compartment seats
In transfer-type showers, the seat shall extend from the back wall to a point within 3 inches (76 mm) of the compartment entry....
-
11B-608.5.2 Standard roll-in type shower compartments
In standard roll-in type shower compartments, the controls, faucets, and the shower spray unit shall be located on the back wall of the compartment adjacent to the seat 16 inches (406 mm...
-
11B-608.5.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located on the side wall of the compartment adjacent to the 16 inches (406 mm) minimum...
-
11B-608.5.1 Transfer type shower compartments
In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1219 mm...
-
11B-608.3.2 Standard roll-in type shower compartments
[2010 ADA Standards] 608.3.2 Standard Roll-In Type Shower Compartments....
-
Controls: ADA Standard Section 608.5
Section 608.5 covers the current ADA Standards for controls in shower compartments.
-
11B-608.3.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
-
11B-608.9 Shower floor or ground surface
Floor or ground surfaces of showers shall comply with Section 11B-302.1 and shall be sloped 1:48 maximum in any direction....
-
Seats: ADA Standard Section 608.4
Section 608.4 covers the current ADA Standards for seats in shower compartments.
-
Clearance: ADA Standard Section 608.2.2.1
Section 608.2.2.1 covers the current ADA Standards for the clearances of standard roll-in type shower compartments.
-
11B-608.6 Shower spray unit and water
A shower spray unit with a hose 59 inches (1499 mm) long minimum that can be used both as a fixed-position shower head and as a hand-held shower shall be provided....
-
Dumpster Enclosures
Dumpster Enclosures Dumpster enclosures used exclusively by employees shall be considered employee work areas based on TAS 201.1; therefore, they must comply with TAS 203.9....
-
General: ADA Standard Section 608.1
Section 608.1 of the ADA Standards covers information in the current ADA Standards for shower compartments.
-
11B-608.2.1 Transfer type shower compartments
mm) wide minimum entry on the face of the shower compartment....
-
11B-608.7 Thresholds
Thresholds in roll-in type shower compartments shall be ½ inch (12.7 mm) high maximum in accordance with Section 11B-303....
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
11B-608.2 Size and clearances for shower compartments
Shower compartments shall have sizes and clearances complying with Section 11B-608.2....
-
Shower Compartments
Shower Compartments....
-
General: ADA Standard Section 610.1
Section 610.1 of the ADA Standards covers information in the current ADA Standards for seats in bathtubs and shower compartments.
-
11B-608.3.1 Transfer type shower compartments
In transfer type compartments, grab bars shall be provided across the control wall and back wall to a point 18 inches (457 mm) from the control wall.
-
11B-608.5 Controls
Controls, faucets, and shower spray units shall comply with Section 11B-309.4. Controls and faucets shall allow the user to close and open the water supply....
-
11B-608.2.2.1 Clearance
A 36 inch (914 mm) wide minimum by 60 inch (1524 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment....
-
Grab Bars [4.20.4] and Controls [4.20.5]
Recommendation: A hose for shower spray units longer than the required minimum of 60 inches is recommended for easier use of the shower spray unit from the seat....