Exterior Sites Recommendation: The 50% scoping required for building interiors should be followed for exterior sites. Where only one unit is provided or where they are spaced at...
Search Results "High Drinking Fountain"
-
Exterior Sites
-
Drinking Fountain Water Flow Tool
Drinking Fountain Water Flow Tool This handy tool was developed by Evan Terry Associates to assist its surveyors in measuring drinking fountain water flow....
-
Spout Height: ADA Standard Section 602.4
Section 602.4 covers the current ADA Standards for the spout height of drinking fountains.
-
Spout Location: ADA Standard Section 602.5
Section 602.5 covers the current ADA Standards for the spout location of drinking fountains.
-
11B-211.1 General
Where drinking fountains are provided on an exterior site, on a floor, or within a secured area they shall be provided in accordance with Section 11B-211....
-
11B-211.1 General
Where drinking fountains are provided on an exterior site, on a floor, or within a secured area they shall be provided in accordance with Section 11B-211....
-
11B-602.1 General
Drinking fountains shall comply with Sections 11B-307 and 11B-602....
-
11B-602.1 General
Drinking fountains shall comply with Sections 11B-307 and 11B-602....
-
11B-602.8 Depth
Wall- and post-mounted cantilevered drinking fountains shall be 18 inches (457 mm) minimum and 19 inches (483 mm) maximum in depth....
-
11B-602.8 Depth
Wall- and post-mounted cantilevered drinking fountains shall be 18 inches (457 mm) minimum and 19 inches (483 mm) maximum in depth....
-
11B-602.6 Water flow
The spout shall provide a flow of water 4 inches (102 mm) high minimum and shall be located 5 inches (127 mm) maximum from the front of the unit....
-
11B-602.6 Water flow
The spout shall provide a flow of water 4 inches (102 mm) high minimum and shall be located 5 inches (127 mm) maximum from the front of the unit....
-
H. Drinking Fountains
Drinking Fountains - Are at least 50% of the drinking fountains on each floor mounted so the spout is no higher than 36"?...
-
Do drinking fountains pose hazards as protruding objects?
Cantilevered units at standard heights for people who stand must be recessed or protected as protruding objects. This is not required for wheelchair accessible units with no more...
-
R212.2 Drinking Fountains
R212.2 Drinking Fountains. Drinking fountains shall comply with sections 602.1 through 602.6 of Appendix D to 36 CFR part 1191....
-
11B-602.4 Spout height
Spout outlets shall be 36 inches (914 mm) maximum above the finish floor or ground.
-
11B-602.5 Spout location
The spout shall be located 15 inches (381 mm) minimum from the vertical support and 5 inches (127 mm) maximum from the front edge of the unit, including bumpers.
-
11B-602.5 Spout location
The spout shall be located 15 inches (381 mm) minimum from the vertical support and 5 inches (127 mm) maximum from the front edge of the unit, including bumpers.
-
11B-602.4 Spout height
Spout outlets shall be 36 inches (914 mm) maximum above the finish floor or ground.
-
602 Drinking Fountains
602 Drinking Fountains...
-
Operable Parts: ADA Standard Section 602.3
Section 602.3 covers the current ADA Standards for the operable parts of drinking fountains.
-
11B-602 Drinking fountains and bottle filling stations
11B-602 Drinking fountains and bottle filling stations...
-
11B-211 Drinking fountains and bottle filling stations
11B-211 Drinking fountains and bottle filling stations...
-
11B-602 Drinking fountains and bottle filling stations
11B-602 Drinking fountains and bottle filling stations...