(h) Dressing Rooms: In alterations where technical infeasibility can be demonstrated, one dressing room for each sex on each level shall be made accessible....
Search Results "Feasibility (Technical, Infeasible, Structural, Maximum Extent)"
-
4.1.6(3)(h) Dressing Rooms
-
Gaps: ADA Standard Section 1002.4.3
are at rest in the load and unload position, the vertical difference between the floors shall be within plus or minus 5/8 inches (16 mm) and the horizontal gap shall be 3 inches (75 mm) maximum...
-
4.1.6(3)(d)(i)
(i) Where it is technically infeasible to comply with clear opening width requirements of 4.13.5, a projection of 5/8 in maximum will be permitted for the latch side stop....
-
§ 36.402(c) To the maximum extent feasible.
(c) To the maximum extent feasible....
-
§ 35.151(b)(3)
(3) Alterations to historic properties shall comply, to the maximum extent feasible, with the provisions applicable to historic properties in the design standards specified in § 35.151(c...
-
233.3.4 Alterations
EXCEPTION: Where compliance with 809.2, 809.3, or 809.4 is technically infeasible, or where it is technically infeasible to provide an accessible route to a residential dwelling unit, the...
-
233.3.4 Alterations
EXCEPTION: Where compliance with 809.2, 809.3, or 809.4 is technically infeasible, or where it is technically infeasible to provide an accessible route to a residential dwelling unit, the...
-
10.3.2(3)
(3) Where technical infeasability [sic] in existing stations requires the accessible route to lead from the public way to a paid area of the transit system, an accessible fare collection...
-
Section 35.151(b)(3) Alterations to historic facilities (Section-by-Section Analysis)
Currently, the regulation provides that alterations to historic facilities shall comply to the maximum extent feasible with section 4.1.7 of UFAS or section 4.1.7 of the 1991 Standards....
-
Sec.36.402(c) To the maximum extent feasible
(c) To the maximum extent feasible....
-
Toilet Stalls [4.17]
Only when technical infeasibility can be demonstrated in alterations may an alternate stall substitute for the required standard stall of Figure 30(a)....
-
Alterations Affecting Primary Function Areas: ADA Standard Section 202.4
Section 202.4 covers the most current ADA Standards for alterations affecting primary function area.
-
Accessible Routes: ADA Standard Section 1002.2
In load or unload areas and on amusement rides, where compliance with 405.2 is not structurally or operationally feasible, ramp slope shall be permitted to be 1:8 maximum. 2....
-
11B-1002.2 Accessible routes
to be 1:8 maximum....
-
11B-1002.2 Accessible routes
to be 1:8 maximum....
-
4.1.6(3)(f)(ii)
(ii) Where it is technically infeasible to alter all performing areas to be on an accessible route, at least one of each type of performing area shall be made accessible....
-
4.1.6(3)(e)(ii)
(ii) Where it is technically infeasible to install a required standard stall (Fig. 30(a)), or where other codes prohibit reduction of the fixture count (i.e., removal of a water closet in...
-
Alterations/ Historic Preservation
Steeper slopes are allowed for short ramps where a 1:12 slope is not technically feasible....
-
Common Questions (Alterations and Additions)
Common Questions
-
Site Constraints
Platform lifts are permitted where "existing or other constraints" make ramp or elevator access "infeasible."...
-
§35.151(d)
(d) Alterations: Historic properties.
-
§ 35.151(b)(3)
(3)
-
F233.3.3 Alterations
EXCEPTION: Where compliance with 809.2, 809.3, or 809.4 is technically infeasible, or where it is technically infeasible to provide an accessible route to a residential dwelling unit, the...
-
202.3 Alterations
In alterations, where compliance with applicable requirements is technically infeasible, the alteration shall comply with the requirements to the maximum extent feasible....