The spout shall be located 15 inches (381 mm) minimum from the vertical support and 5 inches (127 mm) maximum from the front edge of the unit, including bumpers....
Search Results "Drinking Fountain Spout Height"
-
11B-602.5 Spout location
-
4.15.3 Spout Location
The spouts of drinking fountains and water coolers shall be at the front of the unit and shall direct the water flow in a trajectory that is parallel or nearly parallel to the front of the...
-
4.15.3 SPOUT LOCATION
The spouts of drinking fountains and water coolers shall be at the front of the unit and shall direct the water flow in a trajectory that is parallel or nearly parallel to the front of the...
-
Spout Location [4.15.3]
Spout Location [4.15.3] A person using a wheelchair has limited ability to lean over a drinking fountain, especially from a side approach....
-
11B-211.3 More than minimum number
Where more than the minimum number of drinking fountains specified in Section 11B-211.2 are provided, 50 percent of the total number of drinking fountains provided shall comply with Sections...
-
11B-211.3 More than minimum number
Where more than the minimum number of drinking fountains specified in Section 11B-211.2 are provided, 50 percent of the total number of drinking fountains provided shall comply with Sections...
-
11B-211.2 Minimum number
No fewer than two drinking fountains shall be provided....
-
11B-211.2 Minimum number
No fewer than two drinking fountains shall be provided....
-
General: ADA Standard Section 211.1
Section 211.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for drinking fountains.
-
General: ADA Standard Section 602.1
Section 602.1 of the ADA Standards covers information in the current ADA Standards for drinking fountains.
-
211 Drinking Fountains
fountain is provided on a floor there shall be a drinking fountain which is accessible to individuals who use wheelchairs in accordance with 4.15 and one accessible to those who have difficulty...
-
11B-211.1 General
Where drinking fountains are provided on an exterior site, on a floor, or within a secured area they shall be provided in accordance with Section 11B-211....
-
11B-211.1 General
Where drinking fountains are provided on an exterior site, on a floor, or within a secured area they shall be provided in accordance with Section 11B-211....
- Figure 602.5 Drinking Fountain Spout Location – Drawing from the U.S. Access Board
-
11B-602.1 General
Drinking fountains shall comply with Sections 11B-307 and 11B-602....
-
11B-602.1 General
Drinking fountains shall comply with Sections 11B-307 and 11B-602....
-
11B-602.8 Depth
Wall- and post-mounted cantilevered drinking fountains shall be 18 inches (457 mm) minimum and 19 inches (483 mm) maximum in depth....
-
11B-602.8 Depth
Wall- and post-mounted cantilevered drinking fountains shall be 18 inches (457 mm) minimum and 19 inches (483 mm) maximum in depth....
-
211 and 602 Drinking Fountains
The 1991 Standards require wall and post-mounted cantilevered drinking fountains mounted at a height for wheelchair users to provide clear floor space for a forward approach with knee and...
-
Two Drinking Fountains
Many comments considered this section unduly complicated and obscure in potentially requiring at least two units where drinking fountains are provided....
-
R212.2 Drinking Fountains
R212.2 Drinking Fountains. Drinking fountains shall comply with sections 602.1 through 602.6 of Appendix D to 36 CFR part 1191....
-
602 Drinking Fountains
602 Drinking Fountains...
-
Operable Parts: ADA Standard Section 602.3
Section 602.3 covers the current ADA Standards for the operable parts of drinking fountains.