Elevator Door Requirements [§407.3]...
Search Results "Door Signal Device"
-
Elevator Door Requirements [§407.3]
-
Door Closers and Gate Closers: ADA Standard Section 404.2.8.1
Section 404.2.8.1 covers the current ADA Standards for the closing speed of door closers and gate closers.
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor....
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor....
-
§ 38.113(c) Signals
(c) Signals. If doors to the platform close automatically or from a remote location, auditory and visual warning signals shall be provided to alert passengers of closing doors...
-
Door Protective and Reopening Device [4.10.6]
Door reopening devices must be able to detect obstructions without contact; otherwise, they can disrupt the balance of people using crutches or canes....
-
11B-407.2.2.2 Visible signals
Visible signal fixtures shall be centered at 72 inches (1829 mm) minimum above the finish floor or ground....
-
11B-407.2.2.2 Visible signals
Visible signal fixtures shall be centered at 72 inches (1829 mm) minimum above the finish floor or ground....
-
Visible Signals: ADA Standard Section 407.2.2.2
Section 407.2.2.2 covers the current ADA Standards for elevator visible signals.
-
11B-411.4.8.2.2 Signal level
The verbal annunciator signal level shall comply with Section 11B-407.4.8.2.2....
-
11B-411.4.8.2.2 Signal level
The verbal annunciator signal level shall comply with Section 11B-407.4.8.2.2....
-
Must elevator doors remain open for 20 seconds?
LULA swing doors, private residence elevator doors, and platform lift gates and doors must remain open for 20 seconds minimum....
-
11B-407.2.2.3 Audible signals
Audible signals shall sound once for the up direction and twice for the down direction, or shall have verbal annunciators that indicate the direction of elevator car travel....
-
11B-407.2.2.3 Audible signals
Audible signals shall sound once for the up direction and twice for the down direction, or shall have verbal annunciators that indicate the direction of elevator car travel....
-
Audible Signals: ADA Standard Section 407.2.2.3
Section 407.2.2.3 covers the current ADA Standards for elevator audible signals.
-
Door and Signal Timing
Section 407.3.4 specifies door and signal timing....
-
Door and Gate Surfaces: ADA Standard Section 404.2.10
Section 404.2.10 covers the current ADA Standards for door and gate surfaces on manual doors and gates.
-
Inventory Control Devices
Inventory Control Devices It is important that inventory control or security devices not obstruct required maneuvering clearances at doors....
-
407.3.3 Reopening Device
407.3.3 Reopening Device....
-
407.3.3 Reopening Device
Elevator doors shall be provided with a reopening device complying with 407.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed by an...
-
407.3.3 Reopening Device
Elevator doors shall be provided with a reopening device complying with 407.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed by an...
-
11B-404.2.7 Door and gate hardware
mm) maximum above the finish floor or ground provided the self-latching devices are not also self-locking devices and operated by means of a key, electronic opener, or integral combination...
-
11B-404.2.7 Door and gate hardware
mm) maximum above the finish floor or ground provided the self-latching devices are not also self-locking devices and operated by means of a key, electronic opener, or integral combination...
-
2.2.6 Door Use
2.2.6 Door Use Our study of door use had three main objectives all intended to provide groundwork for future studies aimed at design guidelines and standards that would make doors more...