Elevator Car Dimensions (§407.4.1)...
Search Results "Adult Dimension"
Commonly Searched Documents
-
Elevator Car Dimensions (§407.4.1)
-
11B-813.2.11 Privacy latch
Each door to adult changing facilities shall have a privacy latch....
-
11B-813.2.1.4 Capacity
Adult changing tables shall provide a minimum weight capacity of 300 pounds (136 kg)....
-
§ 38.4(a) Dimensional conventions
Dimensions that are not noted as minimum or maximum are absolute....
-
11B-813.2.1.1 Size
Adult changing tables shall have a changing surface of 70 inches (1778 mm) minimum length and 30 inches (762 mm) minimum width....
-
1 - Design and drawing
For example, architects typically use chain dimensioning. If the contractor follows the chain in layout, slight errors can accumulate to the final dimension....
-
11B-249 Adult changing facilities
[See subsections ...]
-
11B-813.2.10 Door swing
provided within the room beyond the arc of the door swing, doors shall be permitted to swing into the clear floor space, clearance required for any fixture, and clearance required for adult...
-
11B-813.2.1.2 Clearance
A 36 inches minimum (914 mm) width side clearance shall be provided along the entire length of one side of adult changing tables....
-
11B-813.1 Location
Adult changing facilities shall be provided within a unisex (single-user or family) toilet room or other similar private room....
-
11B-813.2.1.5 Obstructions
When deployed, changing tables shall not obstruct the required width of an accessible route except as allowed by Section 11B-307.2.
- PC 2000 Hi Lo Adult Changing Table
- Pressalit Care 3000 Adult Changing Table
-
11B-813.2.3 Lavatory
One lavatory in compliance with Section 11B-606.
-
11B-813.2.5 Coat hook
No fewer than one coat hook shall be provided in close proximity to the changing table and within one of the reach ranges specified in Section 11B-308.
-
11B-813.2.7 Accessories
Where provided, no fewer than one of each accessory shall comply with Section 11B-603.5.
-
11B-813.2.6 Shelf
No fewer than one shelf shall be provided in close proximity to the changing table at 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor.
-
11B-249.1.1
Where adult changing facilities are provided, each adult changing facility shall comply with Section 11B-813....
-
11B-249.1 General
Adult changing facilities shall comply with Section 11B-249....
-
Construction and Manufacturing Tolerances
., “tolerated”), variation from a specified dimension resulting from the process of construction or manufacture....
-
104 Conventions
104 Conventions Dimensions. Section 104.1 of the 2010 Standards notes that dimensions not stated as a “maximum” or “minimum” are absolute....
-
General: ADA Standard Section 308.1
Section 308.1: of the ADA Standards covers information in the current ADA Standards for reach ranges.
-
11B-813.2.1 Adult changing table
Adult changing tables shall be fixed to the floor or a wall and shall comply with Section 11B-813.2.1....
-
1.1.1
1.1.1 When a maximum or minimum dimension is a regulatory requirement use a drawing dimension that is less than a maximum limit or more than a minimum limit....