LULA Car Dimensions (§408.4)...
Search Results "Adult Dimension"
Commonly Searched Documents
-
LULA Car Dimensions (§408.4)
-
11B-407.4.1 Car dimensions
Inside dimensions of elevator cars and clear width of elevator doors shall comply with Table 11B-407.4.1....
-
11B-407.4.1 Car dimensions
Inside dimensions of elevator cars and clear width of elevator doors shall comply with Table 11B-407.4.1....
-
1.2.2
1.2.2 Use datum dimensioning referenced to a primary or secondary control point on the construction site when the position of one item is particularly important....
-
11B-813.2.11 Privacy latch
Each door to adult changing facilities shall have a privacy latch....
-
11B-813.2.1.4 Capacity
Adult changing tables shall provide a minimum weight capacity of 300 pounds (136 kg)....
-
11B-813.2.1.1 Size
Adult changing tables shall have a changing surface of 70 inches (1778 mm) minimum length and 30 inches (762 mm) minimum width....
-
11B-813.2.10 Door swing
provided within the room beyond the arc of the door swing, doors shall be permitted to swing into the clear floor space, clearance required for any fixture, and clearance required for adult...
-
A4.8.5 Handrails
The requirements for stair and ramp handrails in this guideline are for adults....
-
A4.8.5 HANDRAILS
The requirements for stair and ramp handrails in this standard are for adults....
-
11B-813.2.1.2 Clearance
A 36 inches minimum (914 mm) width side clearance shall be provided along the entire length of one side of adult changing tables....
-
11B-813.1 Location
Adult changing facilities shall be provided within a unisex (single-user or family) toilet room or other similar private room....
-
11B-813.2.1.5 Obstructions
When deployed, changing tables shall not obstruct the required width of an accessible route except as allowed by Section 11B-307.2.
-
11B-813.2.9 Overlap
Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap.
-
11B-813.2.5 Coat hook
No fewer than one coat hook shall be provided in close proximity to the changing table and within one of the reach ranges specified in Section 11B-308.
-
11B-813.2.7 Accessories
Where provided, no fewer than one of each accessory shall comply with Section 11B-603.5.
-
11B-813.2.6 Shelf
No fewer than one shelf shall be provided in close proximity to the changing table at 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor.
-
11B-813.2.3 Lavatory
One lavatory in compliance with Section 11B-606.
-
7.4.5.1 Size
The passing space shall be either: A space 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum; or The intersection of two trails providing a T-shaped space...
-
Advisory Reach Range for Children
The standards include advisory (non-mandatory) reach ranges based on children’s dimensions that can be followed when operable parts are designed for use by children....
-
104 Conventions
Section 104.1 notes that all dimensions not stated as a "maximum" or "minimum" are absolute and that all dimensions are "subject to conventional industry tolerances."...
-
DSA IR 11B-8 - USE OF PREDETERMINED CONSTRUCTION TOLERANCE GUIDELINES FOR ACCESSIBILITY (with revisions issued through Jan. 2011)
California Department of General Services . Division of the State Architect . Interpretation of Regulations Document IR 11B-8 USE OF PREDETERMINED CONSTRUCTION TOLERANCE...
- Universal Changing Places
-
11B-813.2.4 Waste receptacle
No fewer than one waste receptacle in compliance with Section 11B-603.5.