Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches (1015 mm) maximum above the finish floor or ground....
Search Results "Water Closet Clear Floor Space"
-
603.3 Mirrors
-
11B-603.3 Mirrors
Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches (1016 mm) maximum above the finish floor or ground....
-
11B-703.3.2 Position
ETA Editor's Note CBC Figure 11B-703.3.2 is not intended to suggest that Braille must be multi-lined when the related text is multi-lined, only to illustrate the required position and spacing...
-
407.2.2.2 Visible Signals
Visible signal fixtures shall be centered at 72 inches (1830 mm) minimum above the finish floor or ground....
-
1009.2.1 Elevators required
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, not less than one required accessible means of egress shall be an elevator...
-
Section 35.151(f) Housing at a place of education
There are other differences between the two sets of standards as well with respect to requirements for accessible windows, alterations, kitchens, accessible route throughout a unit, and clear...
-
224.6 Housing at a Place of Education
Kitchens within housing units containing accessible sleeping rooms with mobility features (including suites and clustered sleeping rooms) or on floors containing accessible sleeping rooms...
-
4.19.2 Height and Clearances
Lavatories shall be mounted with the rim or counter surface no higher than 34 in (865 mm) above the finish floor....
- Sloan AD-82 Two Station AER-DEC Integrated Sink with Faucet, Soap Dispenser and Hand Dryer
-
§ 36.304(b)(9)
(9) Installing offset hinges to widen doorways;
-
University of Louisville, Injury Risk Assessment and Prevention (iRAP) Laboratory
The Injury Risk Assessment and Prevention (iRAP) Laboratory is a multi-disciplinary laboratory that conducts state-of-the-art research through the application of engineering and...
-
11B-202.4 Path of travel requirements in alterations, additions and structural repairs
Rearranging toilet partitions to increase maneuvering space. Insulating lavatory pipes under sinks to prevent burns. Installing a raised toilet seat....
- Just Manufacturing 42" Stainless Steel Grab Bar
- Moen Home Care Peened 42" Grab Bar
-
Eliminating Hazards [4.26.4]
Extensions must be rounded or returned to the walls, floors, or posts. Extensions with bottom edges within 27 inches of the floor are detectable within the standard sweep of canes....
-
§27.71(k)
(k) Shared-use automated airport kiosks provided in accordance with paragraph (j) of this section must conform to the following technical accessibility standards with respect to...
-
1134A.6, Item 4
Grab bar reinforcement shall be installed continuous in the walls of showers 32 inches to 38 inches (813 mm to 965 mm) above the floor....
-
PATH OF TRAVEL
(2) An accessible path of travel may consist of walks and sidewalks, curb ramps and other interior or exterior pedestrian ramps; clear floor paths through lobbies, corridors, rooms...
-
OPEN RISER
[DSA-AC] The space between two adjacent stair treads not closed by a riser....
-
OPEN RISER
[DSA-AC] The space between two adjacent stair treads not closed by a riser....
-
Sec.36.404(b)
For example, alterations to floors above or below the accessible ground floor must be accessible regardless of whether the altered facility has an elevator....
-
Thresholds: ADA Standard Section 608.7
Section 608.7 covers the current ADA Standards for thresholds in shower compartments.
-
Bathtub Seats: ADA Standard Section 610.2
Section 610.2 covers the current ADA Standards for bathtub seats.
-
11B-608.7 Thresholds
maximum shall be permitted in transfer type shower compartments in existing facilities where provision of a ½ inch (12.7 mm) high threshold would disturb the structural reinforcement of the floor...

