The counter surface height shall be 38 inches (965 mm) maximum above the finish floor or ground....
Search Results "Shall"
-
11B-904.3.2 Counter
-
11B-1008.2.5.3.1 Handrail gripping surfaces
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 0.95 inch (24 mm) minimum and 1.55 inches (39 mm) maximum....
-
11B-411.2.1.3.2 Touch screen call console arrangement
Where touch screen call consoles are provided, the touch screen shall be located directly above the accessibility function button....
-
11B-411.2.1.2.4 Display screen
Upon activation of the accessibility function button, the display screen shall display information including but not limited to, operating instructions, user input confirmation, elevator...
-
11B-411.2.1.3.1 Keypad call console arrangement
Where keypad call consoles are provided, the display screen shall be located directly above the keypad....
-
11B-809.10.8.7 Mirrors and towel bars
Where mirrors are provided the bottom edge of the reflective surface shall be 40 inches (1016 mm) maximum above the finish floor....
-
11B-403.5 Clearances
Walking surfaces shall provide clearances complying with Section 11B-403.5....
-
11B-203.13 Raised boxing or wrestling rings
Raised boxing or wrestling rings shall not be required to comply with these requirements or to be on an accessible route....
-
11B-407.4.7.1.1 Type
Control buttons shall be identified by raised characters or symbols, white on a black background, complying with Section 11B-703.2 and Braille complying with Section 11B-703.3....
-
11B-609.4 Position of grab bars
Grab bars shall be installed in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
11B-1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (864 mm) maximum above the ground or deck surface....
-
608.2.1 Transfer Type Shower Compartments
Transfer type shower compartments shall be 36 inches (915 mm) by 36 inches (915 mm) clear inside dimensions measured at the center points of opposing sides and shall have a 36 inch (915...
-
1132A.8 Hand-activated door hardware
Hand-activated door latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor....
-
11B-404.2.4 Maneuvering clearances
Minimum maneuvering clearances at doors and gates shall comply with Section 11B-404.2.4....
-
1007.2.1 Buildings with four or more stories
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, at least one required accessible means of egress shall be an elevator complying...
-
1007.4 Elevators
An elevator to be considered part of an accessible means of egress shall comply with the emergency operation and signaling device requirements of Section 2.27 of ASME A17.1....
-
Class Notice
Class Notice - The City shall, publish notice of the Settlement Agreement in the Los Angeles Times, the Los Angeles Daily News, and La Opinion, in addition to its website....
-
F233.4.4.1 Alterations to Vacated Buildings
Where a building is vacated for the purposes of alteration and the altered building contains more than 15 residential dwelling units, at least 5 percent of the residential dwelling units shall...
-
502.4 Floor or Ground Surfaces
Parking spaces and access aisles serving them shall comply with 302. Access aisles shall be at the same level as the parking spaces they serve. Changes in level are not permitted....
-
F213.1 General
Where toilet facilities and bathing facilities are provided, they shall comply with F213....
-
F206.8 Security Barriers
Security barriers, including but not limited to, security bollards and security check points, shall not obstruct a required accessible route or accessible means of egress....
-
233.3.4.1 Alterations to Vacated Buildings
Where a building is vacated for the purposes of alteration, and the altered building contains more than 15 residential dwelling units, at least 5 percent of the residential dwelling units shall...
-
T503.5 Exterior Illumination for Boarding and Alighting Areas
Exterior lighting shall be provided to illuminate walking surfaces of boarding and alighting areas when the doors of non-rail vehicles are open....
-
1003.2.13.1.1 Buildings with four or more stories
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, at least one required accessible means of egress shall be an elevator complying...