The rear edge of a rectangular seat shall be 2½ inches (64 mm) maximum and the front edge 15 inches (381 mm) minimum and 16 inches (406 mm) maximum from the seat wall....
Search Results "Wing Wall"
Commonly Searched Documents
-
11B-610.3.1 Rectangular seats
-
11B-610.3.1 Rectangular seats
The rear edge of a rectangular seat shall be 2½ inches (64 mm) maximum and the front edge 15 inches (381 mm) minimum and 16 inches (406 mm) maximum from the seat wall....
-
610.3.1 Rectangular Seats
The rear edge of a rectangular seat shall be 2½ inches (64 mm) maximum and the front edge 15 inches (380 mm) minimum and 16 inches (405 mm) maximum from the seat wall....
-
608.5.1 Transfer Type Shower Compartments
In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm...
-
Controls [4.21.5]
Controls [4.21.5] Controls and shower units can be located on any wall but where a folding seat is provided they must be located to be within reach of a person on the seat....
-
11B-604.7.2 Disposal units
Sanitary napkin disposal units, if provided, shall comply with Section 11B-309.4 and shall be wall mounted and located on the sidewall between the rear wall of the toilet and the toilet...
-
§ 38.107(a)(3)
(3) A grab bar at least 24 inches long shall be mounted behind the water closet, and a horizontal grab bar at least 40 inches long shall be mounted on at least one side wall, with one end...
-
§ 38.123(a)(3)
(3) A grab bar at least 24 inches long shall be mounted behind the water closet, and a horizontal grab bar at least 40 inches long shall be mounted on at least one side wall, with one end...
-
11B-608.5.1 Transfer type shower compartments
In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1219 mm...
-
604.2 Location
The water closet shall be positioned with a wall or partition to the rear and to one side....
-
704.11.1 Parapet construction
Parapets shall have the same fire-resistance rating as that required for the supporting wall, and on any side adjacent to a roof surface, shall have noncombustible faces for the uppermost...
-
Clear Floor or Ground Space: ADA Standard Section 804.3.1
conditions are met: (a) the cabinetry can be removed without removal or replacement of the kitchen work surface; (b) the finish floor extends under the cabinetry; and (c) the walls...
-
Living Room
Arms well forward on chairs Biodegradable grass cloth Wall texture offers traction when leaning on the wall to prevent slip and fall....
-
610.3.1 Rectangular Seats
The rear edge of a rectangular seat shall be 2½ inches (64 mm) maximum and the front edge 15 inches (380 mm) minimum and 16 inches (405 mm) maximum from the seat wall....
-
804.2.1 Pass Through Kitchen
In pass through kitchens where counters, appliances or cabinets are on two opposing sides, or where counters, appliances or cabinets are opposite a parallel wall, clearance between all opposing...
-
11B-804.2.1 Pass through kitchen
In pass through kitchens where counters, appliances or cabinets are on two opposing sides, or where counters, appliances or cabinets are opposite a parallel wall, clearance between all opposing...
-
11B-604.7.2 Disposal units
Sanitary napkin disposal units, if provided, shall comply with Section 11B-309.4 and shall be wall mounted and located on the sidewall between the rear wall of the toilet and the toilet...
-
11B-804.2.1 Pass through kitchen
In pass through kitchens where counters, appliances or cabinets are on two opposing sides, or where counters, appliances or cabinets are opposite a parallel wall, clearance between all opposing...
-
7(2)(b)(iv)
In locations where toilets are adjacent to walls or bathtubs, the center line of the fixture is a minimum of 1'6" from the obstacle....
-
5.3.4 Grab Bars
Where walls or partitions are provided, grab bars complying with ABAAS section 604.5 shall be provided....
-
3. Protruding Objects
[ADA Stds. 4.4] Note: These objects may be wall mounted or free standing....
-
5.3.4 Grab Bars
Where walls or partitions are provided, grab bars complying with ABAAS section 604.5 shall be provided....
-
1134A.5 Bathtubs
The controls shall be on the wall at the foot of the bathtub. The edge of the clear floor space shall be flush with the control wall surface....
-
Accessible Pathway & Corridor: Minimum Clear Width Required for 90-degree Turn
These data are based on measurements of wheeled mobility users performing 90-degree turns in a hallway, built with mock walls. The outside wall of the hallway was fixed....