- Neo-Metro Wall Mounted PAT Basin Featuring Dyson® Airblade™ Tap/Hand Dryer Video Demo
-
11B-610.3 Shower compartment seats
A seat in a standard roll-in shower compartment shall be a folding type, shall be installed on the side wall adjacent to the controls, and shall extend from the back wall to a point within...
-
11B-505.10.1 Top and bottom extension at ramps
Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent ramp run. ...
-
11B-505.10.1 Top and bottom extension at ramps
Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent ramp run. ...
-
704.7 Unexposed surface temperature
Where protected openings are not limited by Section 704.8, the limitation on the rise of temperature on the unexposed surface of exterior walls the exterior wall in any story, the total...
-
Inpro Corporation JointMaster® 316 Single Sightline for Carpet Floor Expansion Joint Covers Floor to Wall
Requires the Premium User plan or above. (Login or upgrade your account!)
-
11B-610.3 Shower compartment seats
A seat in a standard roll-in shower compartment shall be a folding type, shall be installed on the side wall adjacent to the controls, and shall extend from the back wall to a point within...
-
11B-610.3 Shower compartment seats
A seat in a standard roll-in shower compartment shall be a folding type, shall be installed on the side wall adjacent to the controls, and shall extend from the back wall to a point within...
- Bobrick Two-Wall Tub/Shower Toilet Compartment Grab Bar Peened B-68137.99
- Murdock Manufacturing Barrier-Free 14-Gage Stainless Steel Wall Mount Water Cooler
- Bobrick Two-Wall Tub/Shower Toilet Compartment Grab Bar Peened B-5837.99
-
11B-608.5.2 Standard roll-in type shower compartments
In standard roll-in type shower compartments, operable parts of controls and faucets shall be installed on the back wall of the compartment adjacent to the seat wall 19 inches (483 mm) minimum...
-
11B-608.5.2 Standard roll-in type shower compartments
In standard roll-in type shower compartments, operable parts of controls and faucets shall be installed on the back wall of the compartment adjacent to the seat wall 19 inches (483 mm) minimum...
-
Section 4.1.5, Additions (Section-By-Section Analysis and Response to Comments)
For example, if a museum adds a new wing that does not have a separate entrance as part of the addition, an accessible path of travel would have to be provided through the existing building...
-
11B-604.8.1.5 Grab bars
A side-wall grab bar complying with Section 11B-604.5.1 shall be provided and shall be located on the wall closest to the water closet....
-
11B-608.5.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, operable parts of controls and faucets shall be installed on the side wall of the compartment adjacent to the seat wall 19 inches (483 mm)...
-
11B-608.5.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, operable parts of controls and faucets shall be installed on the side wall of the compartment adjacent to the seat wall 19 inches (483 mm)...
-
Location: ADA Standard Section 703.4.2
Where there is no wall space at the latch side of a single door or at the right side of double doors, signs shall be located on the nearest adjacent wall....
-
608.3.1 Transfer Type Shower Compartments
In transfer type compartments, grab bars shall be provided across the control wall and back wall to a point 18 inches (455 mm) from the control wall....
-
Height and Depth: ADA Standard Section 605.2
Section 605.2 covers the current ADA Standards for the height and depth of urinals.
-
Bottom Extension at Stairs: ADA Standard Section 505.10.3
Section 505.10.3 covers the current ADA Standards for the handrail extensions at the bottom of the stairs.
-
Top and Bottom Extension at Ramps: ADA Standard Section 505.10.1
Section 505.10.1 covers the current ADA Standards for the top and bottom handrail extensions at ramps.
-
11B-804.2.2 U-Shaped
In U-shaped kitchens enclosed on three contiguous sides, clearance between all opposing base cabinets, counter tops, appliances, or walls within kitchen work areas shall be 60 inches (1524...
-
11B-505.10.2 Top extension at stairs
Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight....