Reinforcement for grabs bars shall comply with the following: Continuous reinforcement shall be installed in the walls of showers 30 inches (762 mm) maximum to 38 inches (965 mm) minimum...
Search Results "Vertical Actuation Bar"
Commonly Searched Documents
-
11B-809.10.6.4 Reinforcement for grab bars
-
Can curbs be used to indicate areas with less than 80” of vertical clearance?
The standards specify a maximum height (27”) for the leading edge of barriers so they are within cane sweep, but a minimum height is not specified. Curbs may be mistaken for a step...
-
11B-212.1 General
Where provided, kitchens, kitchenettes, wet bars and sinks shall comply with Section 11B-212. ...
-
11B-212.1 General
Where provided, kitchens, kitchenettes, wet bars and sinks shall comply with Section 11B-212. ...
-
11B-809.10.8.7 Mirrors and towel bars
Where towel bars are provided they shall be installed 40 inches (1016 mm) maximum above the finish floor to the top of the bar....
-
609.2.1 Circular Cross Section
Grab bars with circular cross sections shall have an outside diameter of 1¼ inches (32 mm) minimum and 2 inches (51 mm) maximum....
-
1g
Is there a horizontal grab bar on the wall opposite the seat as shown in Figure 37(a) above?...
-
11B-609.2.1 Circular cross section
Grab bars with circular cross sections shall have an outside diameter of 1¼ inches (32 mm) minimum and 2 inches (51 mm) maximum....
-
11B-609.2.1 Circular cross section
Grab bars with circular cross sections shall have an outside diameter of 1¼ inches (32 mm) minimum and 2 inches (51 mm) maximum....
-
Dispensers: ADA Standard Section 604.9.6
Section 604.9.5 covers the current ADA Standards for dispensers in children's use toilet compartments.
-
11B-206.2.3.2 Distance to Elevators
In new construction of buildings where elevators are required by Section 11B-206.2.3, and which exceed 10,000 square feet (929 m2) on any floor, an accessible means of vertical access via...
-
11B-206.2.3.2 Distance to Elevators
In new construction of buildings where elevators are required by Section 11B-206.2.3, and which exceed 10,000 square feet (929 m2) on any floor, an accessible means of vertical access via...
-
11B-206.2.3.2 Distance to Elevators
In new construction of buildings where elevators are required by Section 11B-206.2.3, and which exceed 10,000 square feet (929 m2) on any floor, an accessible means of vertical access via...
-
1017.4.1 Size
Vertical alignment at the intersection of the trails that form the T-shaped space shall be nominally planar. Advisory 1017.4.1 Size. ...
-
Protruding Objects [1016.9]
To prevent injuries to people who are blind or have low vision, whenever possible, maintain the vertical clearance free of tree branches a minimum of 80 inches above the ground surface along...
-
1017.4.1 Size
Vertical alignment at the intersection of the trails that form the T-shaped space shall be nominally planar. Advisory 1017.4.1 Size....
-
609.2.1 Circular Cross Section
Grab bars with circular cross sections shall have an outside diameter of 1 1/4 inches (32 mm) minimum and 2 inches (51 mm) maximum....
-
609.2.1 Circular Cross Section
Grab bars with circular cross sections shall have an outside diameter of 1 1/4 inches (32 mm) minimum and 2 inches (51 mm) maximum....
-
609.2.1 Circular Cross Section
Grab bars with circular cross sections shall have an outside diameter of 1¼ inches (32 mm) minimum and 2 inches (51 mm) maximum....
-
4.26.4 Eliminating Hazards
A handrail or grab bar and any wall or other surface adjacent to it shall be free of any sharp or abrasive elements. Edges shall have a minimum radius of 1/8 in (3.2 mm)....
-
4.26.4 ELIMINATING HAZARDS
A handrail or grab bar and any wall or other surface adjacent to it shall be free of any sharp or abrasive elements. Edges shall have a minimum radius of 1/8 in (3.2 mm)....
-
11B-604.9.6 Dispensers
There shall be a clearance of 1½ inches (38 mm) minimum below the grab bar. Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow....
-
11B-609.2.1 Circular cross section
Grab bars with circular cross sections shall have an outside diameter of 1¼ inches (32 mm) minimum and 2 inches (51 mm) maximum....