In a wheelchair accessible compartment with an in-swinging door, a minimum 60 inches (1524 mm) wide by 36 inches (914 mm) deep maneuvering space shall be provided in front of the clearance...
Search Results "Shower Compartment"
Commonly Searched Documents
-
11B-604.8.1.1.1 Maneuvering space with in-swinging door
-
11B-604.8.1.1.1 Maneuvering space with in-swinging door
In a wheelchair accessible compartment with an in-swinging door, a minimum 60 inches (1524 mm) wide by 36 inches (914 mm) deep maneuvering space shall be provided in front of the clearance...
-
A4.23.3 Clear Floor Space
Figure A7 shows two possible configurations of a toilet room with a roll-in shower. The specific shower shown is designed to fit exactly within the dimensions of a standard bathtub....
-
§ 38.127(b)
(b) Each accessible compartment shall contain a restroom complying with §38.123(a) which can be entered directly from such compartment....
-
11B-604.8.1.1.1 Maneuvering space with in-swinging door
In a wheelchair accessible compartment with an in-swinging door, a minimum 60 inches (1524 mm) wide by 36 inches (914 mm) deep maneuvering space shall be provided in front of the clearance...
-
4.26.3(1)
(1) Bending stress in a grab bar or seat induced by the maximum bending moment from the application of 250 lbf (1112N) shall be less than the allowable stress for the material of the...
-
4.26.3(4)
(4) Tensile force induced in a fastener by a direct tension force of 250 lbf (1112N) plus the maximum moment from the application of 250 lbf (1112N) shall be less than the allowable...
-
4.26.3(2)
(2) Shear stress induced in a grab bar or seat by the application of 250 lbf (1112N) shall be less than the allowable shear stress for the material of the grab bar or seat. If the...
-
4.26.3(3)
(3) Shear force induced in a fastener or mounting device from the application of 250 lbf (1112N) shall be less than the allowable lateral load of either the fastener or mounting...
-
11B-610.3.2 L-shaped seats
FIGURE 11B-610.3.2 L-SHAPED SHOWER SEAT...
-
610.3.2 L-Shaped Seats
Figure 610.3.2 L-Shaped Shower Seat...
-
610.3.2 L-Shaped Seats
[ECTCR UFAS 4.21.3, Fig. 36, 4.34.5.5(2)] Figure 610.3.2 L-Shaped Shower Seat...
- Hadrian Inc. Powder Coated Toilet Partition
-
608.3 Grab Bars (Exception 2)
608.3 Grab Bars (Exception 2) Exception 2 to this section permits grab bars to not be installed in shower compartments in residential dwelling units required to provide mobility features...
-
604.8.1.6 Lavatory
In new construction, the wheelchair accessible toilet compartment shall contain an accessible lavatory within it, which must be at least 19 inches wide by 17 inches deep, nominal size, and...
- Bobrick Folding Shower Seat B-517
- Bobrick Folding Shower Seat B-518
-
Guest Bathrooms
Remind appropriate staff frequently. 608.5.2 Standard Roll-In Type Shower Compartments....
-
11B-224.8.2 More than 50-bed facilities
Facilities with more than 50 beds that provide common use bathing facilities, shall provide at least one roll-in shower with a seat that complies with Section 11B-608....
-
11B-224.8.2 More than 50-bed facilities
Facilities with more than 50 beds that provide common use bathing facilities, shall provide at least one roll-in shower with a seat that complies with Section 11B-608....