The landing clear length shall be 36 inches (915 mm) minimum. The landing clear width shall be at least as wide as the curb ramp, excluding flared sides, leading to the landing....
Search Results "Door Clear Width"
Commonly Searched Documents
-
406.4 Landings
-
404.2.9 Door and Gate Opening Force
404.2.9 Door and Gate Opening Force. Fire doors shall have a minimum opening force allowable by the appropriate administrative authority....
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide...
-
11B-409.3.1 Power operation
Elevator car and hoistway doors and gates shall be power operated and shall comply with ANSI/BHMA A156.19....
-
Position: ADA Standard Section 305.5
Section 305.5 covers the current ADA Standards for the positioning of clear floor and ground space.
-
7.4.5 Passing Spaces
Trails with a clear tread width less than 60 inches (1525 mm) shall provide passing spaces complying with 7.4.5 at intervals of 1000 feet (300 m) maximum. ...
-
A4.17.5 Doors
To make it easier for wheelchair users to close toilet stall doors, doors can be provided with closers, spring hinges, or a pull bar mounted on the inside surface of the door near the hinge...
-
A4.17.5 DOORS
To make it easier for wheelchair users to close toilet stall doors, doors can be provided with closers, spring hinges, or a pull bar mounted on the inside surface of the door near the hinge...
-
3.3.16 Door Use
Differences between the gender composition, occupied width, occupied length and maximum power grip strength were fairly modest....
-
11B-405.7.5 Doorways
Doors, when fully open, shall not reduce the required ramp landing width by more than 3 inches (76 mm)....
-
§ 38.23(b)(6) Platform surface
The platform shall have a minimum clear width of 28 1/2 inches at the platform, a minimum clear width of 30 inches measured from 2 inches above the platform surface to 30 inches above the...
-
Is automation of doors required?
Automation of doors is not required by the Standards, but it is highly recommended for entrance doors where the opening force is significant....
-
11B-407.2.1.3 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided at call controls. Advisory 11B-407.2.1.3 Clear floor or ground space....
-
11B-305 Clear floor or ground space
[See subsections ...]
-
407.3.5 Door Delay
407.3.5 Door Delay. Elevator doors shall remain fully open in response to a car call for 3 seconds minimum....
-
Clear Floor Space: ADA Standard Section 606.2
Section 606.2 covers the current ADA Standards for clear floor space at lavatories and sinks.
-
Elevated Accessible Routes
A typical elevated accessible route might include the following: 36-inch (915 mm) clear width 32-inch (815 mm) narrowed width permitted for 24-inch (610 mm) length to accommodate...
-
404.2.9 Door and Gate Opening Force
The force for pushing or pulling open a door or gate other than fire doors shall be as follows: 1. Interior hinged doors and gates: 5 pounds (22.2 N) maximum. 2....
-
404.2.9 Door and Gate Opening Force
The force for pushing or pulling open a door or gate other than fire doors shall be as follows: 1. Interior hinged doors and gates: 5 pounds (22.2 N) maximum. 2....
- Figure 406.4 Landings at the Top of Curb Ramps – Drawing from the U.S. Access Board
-
11B-1005.4 Clear floor or ground space
At each location where there are railings, guards, or handrails complying with Section 11B-1005.2.1, a clear floor or ground space complying with Section 11B-305 shall be provided....
-
11B-404.3.2 Maneuvering clearance
Clearances at power-assisted doors and gates shall comply with Section 11B-404.2.4....
-
3.3.3 Clear Floor Width
3.3.3 Clear Floor Width The findings on clear floor width are based on the findings on occupied width from anthropometric studies shown in Figure 3‒3....
-
Maneuvering Clearance: ADA Standard Section 404.3.2
Section 404.3.2 covers the current ADA Standards for maneuvering clearance at automatic and power-assisted doors and gates.