For imaging equipment, the aisle width requirements shall apply to only those sides of the equipment where staff typically work to provide medical care to patients, including assisted transfer...
Search Results "Side Transfer Surface"
-
11B-203 General exceptions
-
How should we describe facilities that only meet some of the accessibility guidelines?
While the side entrance was being renovated to make it accessible, a doorbell with the International Symbol of Accessibility (the wheelchair symbol) was provided on the kiosk in front of...
-
SIDEWALK
[DSA-AC] A surfaced pedestrian way contiguous to a street used by the public. (As differentiated from the definition of “Walk”.) Advisory Definition of SIDEWALK. ...
-
405.9.2 Curb or Barrier
curb or barrier shall be provided that prevents the passage of a 4 inch (100 mm) diameter sphere, where any portion of the sphere is within 4 inches (100 mm) of the finish floor or ground surface...
-
7.4.6 Tread Obstacles
Where the trail surface is paved or is elevated above the natural ground, tread obstacles shall not exceed ½ inch (13 mm) in height measured vertically to the highest point. ...
-
R406.2 Unobstructed Forward Reach
Where a forward reach is unobstructed, the high forward reach shall be 1220 mm (4.0 ft) maximum and the low forward reach shall be 380 mm (1.25 ft) minimum above the finish surface....
-
Check-Out Areas [8.3]
Check-Out Areas [8.3] Check-out counters at accessible lanes are held to a maximum surface height of 36 inches....
-
4.7.5 Openings
Openings in surface of the clear floor or ground spaces required by section 2.0 shall not allow passage of a sphere more than 1/2 inch (13 mm) in diameter....
-
WALK
[DSA-AC] An exterior prepared surface for pedestrian use, including pedestrian areas such as plazas and courts. (As differentiated from the definition of “Sidewalk”.)...
-
11B.707.7.1.2 Angle-mounted display screen
viewer 30 degrees to less than 60 degrees from vertical, the center line of the display screen and other display devices shall be no more than 44 inches (1118 mm) above the floor or ground surface...
-
WALK
[DSA-AC] An exterior prepared surface for pedestrian use, including pedestrian areas such as plazas and courts. (As differentiated from the definition of “Sidewalk”.)...
-
405.9.2 Curb or Barrier
curb or barrier shall be provided that prevents the passage of a 4 inch (100 mm) diameter sphere, where any portion of the sphere is within 4 inches (100 mm) of the finish floor or ground surface...
- AccessaBath Shower Systems
- Greenfields Outdoor Fitness Accessible Reverse Butterfly GR2005-1-90-W
- Greenfields Outdoor Fitness Accessible Butterfly GR2005-1-08-W
-
Overlapping Clear Floor Space
The Board has clarified that accessible lavatories are permitted to overlap clear floor space "opposite the shower compartment side where shower controls are positioned or where a seat is...
-
Detailed Age Demographics
For phase 2 there is a small gap in the distribution around 25-35 years old causing the distribution on either side to be greater (Figure D2). Table D2....
-
25.1 Q. It appears from Figure 2(c) of the Guidelines (under Requirement 5) that there is a 34 inch height requirement for kitchen counters and vanities. Is this true?
Figure 2(c) of the Guidelines is illustrating the maximum side reach range over an obstruction....
-
§ 38.91(d)
with the “one-car-per-train rule” at §37.93 of this title shall comply with §§38.93(e), 38.95(a) and 38.107 of this part and shall have, in new and key stations at least one door on each side...
-
WALK
[DSA-AC] An exterior prepared surface for pedestrian use, including pedestrian areas such as plazas and courts. (As differentiated from the definition of “Sidewalk”.)...
-
11B.707.7.1.3 Horizontally mounted display screen
90 degrees (horizontal) tipped away from the viewer, the center line of the display screen and other display devices shall be no more than 34 inches (864 mm) above the floor or ground surface...
-
705.1.2 Dome Spacing
Truncated domes in a detectable warning surface shall have a center-to-center spacing of 1.6 inches (41 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
-
R402.4 Reduced Vertical Clearance
The leading edge of the guardrail or barrier shall be located 685 mm (2.25 ft) maximum above the finish surface....
-
R409.10.1 Top and Bottom Extension at Ramps
Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent ramp run....