mm) to less than or equal to 70 inches (1778 mm) less than 72 inches (1829 mm) 5/8 inch (15.9 mm) 72 inches (1829 mm) and greater 5/8 inch (15.9 mm), plus 1/...
Search Results "9-1-1 Service"
Commonly Searched Documents
-
11B-703.5.5 Character height
-
11B-703.5.5 Character height
mm) to less than or equal to 70 inches (1778 mm) less than 72 inches (1829 mm) 5/8 inch (15.9 mm) 72 inches (1829 mm) and greater 5/8 inch (15.9 mm), plus 1/...
- AJW Architectural Products U122 128 oz. Dual Valve Liquid Soap Dispenser w/ Shelf - Surface Mounted
- AJW Architectural Products U120 128 oz. Single Valve Liquid Soap Dispenser w/ Shelf - Surface Mounted
-
What Kinds Of Tests Are Covered?
certification, or credentialing for secondary or postsecondary education, professional, or trade purposes are covered by the ADA and testing accommodations, pursuant to the ADA, must be provided.1...
-
11B-206.4 Entrances
Exceptions: 1. Reserved. [2010 ADAS] 1. ...
-
603.2.3 Door Swing
EXCEPTIONS: 1....
-
603.2.3 Door Swing
EXCEPTIONS: 1....
-
5.4.7 Transfer Support Gripping Surface Clearance Recommendation for M301 and M302
NPRM Preamble Discussion: The Access Board is considering whether 1½ inches minimum clearance around the gripping surface would be appropriate for transfer supports on diagnostic equipment...
-
302.2 Carpet
Pile height shall be 1/2 inch (13 mm) maximum. Exposed edges of carpet shall be fastened to floor surfaces and shall have trim on the entire length of the exposed edge....
-
Participants
Participants were eligible to participate if they (1) were at least 7 years old, (2) self-reported ability to perform independent transfers to/from a WMD with or without a transfer aide,...
-
704.9 Vertical separation of openings
Such openings shall be separated vertically at least 3 feet (914 mm) by spandrel girders, exterior walls or other similar assemblies that have a fire resistance rating of at least 1 hour...
-
101.1 General
This code is adopted as part of the Florida Building Code by law, s.553.73(1)(a), Florida Statutes....
-
Guidelines for Requirement 3
The Guidelines provide separate guidance for (1) doors that are part of an accessible route in the public and common use areas of multifamily dwellings, including entry doors to individual...
-
603.2.3 Door Swing
EXCEPTIONS: 1....
-
11B-504.5 Nosings
The permitted projection of the nosing shall extend 1¼ inches (32 mm) maximum over the tread below....
-
11B-607.4 Grab bars
Exceptions: 1. Reserved [2010 ADAS] 1. ...
-
Elevated Dune Crossings
An dune crossing that is elevated or has a slope that exceeds 1:20 (5 percent) that is part of a beach access route must have handrails and edge protection (figure 118)....
-
Character Height [4.30.3]
Consider a minimum 1 inch cap height for every 25 feet of viewing distance (horizontal) with 5/8 inch the minimum as recommended by SEGD....
-
Treads and Risers [4.9.2], Nosings [4.9.3]
., projecting more than 1 1/2 inches) can catch the toe. Angled or rounded nosings or sloped risers help prevent this hazard and provide a smoother transition....
-
1016.1 General
Exception 1 applies to alterations of existing camping facilities, picnic facilities, and trailheads. Exception 2 applies to new construction and alterations of viewing areas....
-
11B-504.5 Nosings
The permitted projection of the nosing shall extend 1¼ inches (32 mm) maximum over the tread below....
-
11B-206.4 Entrances
Exceptions: 1. Reserved. [2010 ADAS] 1. ...
-
11B-504.5 Nosings
The permitted projection of the nosing shall extend 1¼ inches (32 mm) maximum over the tread below....