If seating for people in wheelchairs is provided at tables, counters, and work surfaces, knee spaces at least 27 in (685 mm) high, 30 in (760 mm) wide, and 19 in (485 mm) deep shall be provided...
Search Results "Side Transfer Surface"
-
4.32.3 KNEE CLEARANCES
- Sargent 351 Series Aluminum Door Closer
-
Work Areas [4.1.1(3)]
Areas used only by employees as work areas include business or administrative offices and the receptionist side of counters, research facilities, supply rooms and laboratories....
-
Stabila slope meter is easy to read
I like this slope meter because of the readings provided on the top and the side of the slope meter. Makes documentation with photos very easy in the field....
-
1016.5 Obstacles
EXCEPTION: Where the surface is other than asphalt, concrete, or boards, obstacles shall be permitted to not exceed 1 inch (25 mm) in height measured vertically to the highest point....
-
11B-505.10.3 Bottom extension at stairs
Extension shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight....
-
Finish and Contrast [4.30.5]
Consideration should also be given to light sources and the ambient lighting to prevent glare on sign surfaces....
-
Roughness Measurement
The surface profiles were measured with a custom-built pathway measurement tool (PathMeT), which was created from a power WC frame that was instrumented with a wheel encoder and an Acuity...
-
1016.5 Obstacles
EXCEPTION: Where the surface is other than asphalt, concrete, or boards, obstacles shall be permitted to not exceed 1 inch (25 mm) in height measured vertically to the highest point....
-
1.1.16 Alternate measurement tools
Measure running slope along the same lines of measurements as stated in Section 1.1.13 Although the F - number system can be used to measure surface flatness for smooth surfaces it requires...
-
Section 35.151(i) Curb ramps (Section-by-Section Analysis)
Upon further consideration, however, the Department has concluded that the regulation should acknowledge that there are times when there are transitions from sidewalk to road surface that...
-
§ 38.159(c)(8) Handrails
grasp them from outside the vehicle while starting to board, and to continue to use them throughout the boarding process, and shall have the top between 30 inches (760 mm) above the ramp surface...
-
11B-705.1.1.2 Dome spacing
Truncated domes in a detectable warning surface shall have a center-to-center spacing of 2.3 inches (58 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
- Bradley 2-Stall Seat Cover/Tissue Dispenser 5921
-
Summary of the project
Summary of the project Throughout the course of the project representatives from various trade organizations that represent the following materials that may be used for exterior surfaces...
- Touch Mapper Tactile Street Maps
- GE® 30" Free-Standing Electric Range JB450RFSS
-
1134A.6, Item 2
The floor surfaces shall be of Carborundum or grit-faced tile or of material providing equivalent slip resistance....
-
T405.3 Visual Contrast
The stripe shall be 1 inch (25 mm) wide minimum and shall contrast visually with the rest of the step tread or circulation path surface either light-on-dark or dark-on-light....
-
R405.3.4 Clearance Reduction
Between 230 mm (9 in) and 685 mm (2.25 ft) above the finish surface, the knee clearance shall be permitted to reduce at a rate of 25 mm (1 in) in depth for each 150 mm (6 in) in height....
-
6.10 Openings
Openings in the surface of beach access routes and their related resting intervals may be up to 1/2 inch (13 millimeters) wide....
-
1134A.6, Item 2
The floor surfaces shall be of Carborundum or grit-faced tile or of material providing equivalent slip resistance....
-
11B-809.10.6.2 Slope