- Georgia-Pacific Rollmastr 3000® Vertical 2 Roll High Capacity Bathroom Tissue Dispenser
-
Spout Location: ADA Standard Section 602.5
Section 602.5 covers the current ADA Standards for the spout location of drinking fountains.
-
11B-602.5 Spout location
The spout shall be located 15 inches (381 mm) minimum from the vertical support and 5 inches (127 mm) maximum from the front edge of the unit, including bumpers....
-
11B-602.5 Spout location
The spout shall be located 15 inches (381 mm) minimum from the vertical support and 5 inches (127 mm) maximum from the front edge of the unit, including bumpers....
-
Structural Strength: ADA Standard Section 610.4
Section 610.4 covers the current ADA Standards for the structural strength of seats.
-
Structural Strength: ADA Standard Section 903.6
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or...
-
11B-610.4 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or...
-
11B-610.4 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or...
-
Structural Strength: ADA Standard Section 609.8
Section 609.8 covers the current ADA Standards for the structural strength of grab bars.
-
11B-609.8 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener, mounting device,...
-
11B-407.4.10.3 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the support rail, fastener, mounting device...
-
11B-609.8 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener, mounting device,...
-
11B-407.4.10.3 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the support rail, fastener, mounting device...
-
1015.2 Where required
shall be located along open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps and landings, that are located more than 30 inches (762 mm) measured vertically...
-
Automatic and Power-Assisted Doors and Gates: ADA Standard Section 404.3
Section 404.3 covers the current ADA Standards for automatic and power-assisted doors and gates.
-
PLATFORM (WHEELCHAIR) LIFT
mechanism equipped with a car or platform or support that serves two landings of a building or structure and is designed to carry a passenger or passengers and/or luggage or other material a vertical...
-
PLATFORM (WHEELCHAIR) LIFT
mechanism equipped with a car or platform or support that serves two landings of a building or structure and is designed to carry a passenger or passengers and/or luggage or other material a vertical...
-
General: ADA Standard Section 105.1
Section 105.1 of the ADA Standards covers information on the Referenced Standards throughout the ADA Standards.
-
11B-307.4.1 Guy braces
Where a guy support is used within either the width of a circulation path or 24 inches maximum outside of a circulation path, a vertical guy brace, sidewalk guy or similar device shall be...
-
11B-307.4.1 Guy braces
Where a guy support is used within either the width of a circulation path or 24 inches maximum outside of a circulation path, a vertical guy brace, sidewalk guy or similar device shall be...
-
Height: ADA Standard Section 505.4
Section 505.4 covers the current ADA Standards for the height of the top of the gripping surface of handrails.
-
11B-505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (864 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
11B-505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (864 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
1127B.5, Item 4
at the upper end of each curb ramp over its full width to permit safe egress from the ramp surface, or the slope of the fanned or flared sides of the curb ramp shall not exceed one unit vertical...