§ 37.103 [Amended] 7. In § 37.103 (b) and (c), remove the words “or an over-the-road bus,”.
Search Results "Vehicle Overhang"
Commonly Searched Documents
-
7. In § 37.103 (b) and (c), remove the words “or an over-the-road bus,”
-
T602 Wheelchair Spaces
The technical requirements for wheelchair spaces include provisions on surfaces, approach, and size. Under the final rule, as with the existing guidelines, one full unobstructed side...
-
§ 38.83(b)(8) Platform entrance ramp
(8) Platform entrance ramp. The entrance ramp, or loading-edge barrier used as a ramp, shall not exceed a slope of 1:8 measured on level ground, for a maximum rise of 3 inches, and...
-
§ 38.159(b)(8) Platform entrance ramp
(8) Platform entrance ramp. The entrance ramp, or loading-edge barrier used as a ramp, shall not exceed a slope of 1:8, measured on level ground, for a maximum rise of 3 inches (75...
-
§ 38.95(a)(2) Exception
(2) Exception. If level-entry boarding, portable or platform lifts, ramps or bridge plates meeting the applicable requirements of this section are provided on station platforms or...
-
§ 38.93(d)(3) Exception
(3) Exception. Where platform set-backs do not allow the horizontal gap or vertical alignment specified in paragraph (d)(1) or (d)(2) of this section, car, platform or portable lifts...
-
§ 37.7(b)(1)
(1) For purposes of implementing the equivalent facilitation provision in §38.2 of this subtitle, the following parties may submit to the Administrator of the applicable operating...
-
11B-812.8.2 Five to twenty-five
Where five to twenty-five total EVCS are provided, one van accessible EVCS shall be identified by an ISA complying with Section 11B-703.7.2.1. The required standard accessible EVCS...
-
11B-812.8.3 Twenty-six or more
Where twenty-six or more total EVCS are provided, all required van accessible and all required standard accessible EVCS shall be identified by an ISA complying with Section...
-
11B-812.8.3 Twenty-six or more
Where twenty-six or more total EVCS are provided, all required van accessible and all required standard accessible EVCS shall be identified by an ISA complying with Section...
-
11B-812.8.2 Five to twenty-five
Where five to twenty-five total EVCS are provided, one van accessible EVCS shall be identified by an ISA complying with Section 11B-703.7.2.1. The required standard accessible EVCS...
- Adaptive Engineering Inc. Mobilift TX Wheelchair Lift for Rail Access
-
T704 Announcement Systems
With respect to visible components, route identification systems are required to provide signs displaying route information on the front and boarding sides of the vehicle....
-
When do path of travel and/or accessible routes apply? …new construction? …alterations to a parking area? …alterations to a building associated with parking, such as expansion or remodel?
RESPONSE: In each case EVCS required to be accessible must have an accessible route to the facility entrance (see CBC Section 11B-812.5.1) and an accessible route from the vehicle space...
-
503.4 Floor and Ground Surfaces
Vehicle pull-up spaces and access aisles serving them shall comply with 302. Access aisles shall be at the same level as the vehicle pull-up space they serve....
-
11B-503.4 Floor and ground surfaces
Vehicle pull-up spaces and access aisles serving them shall comply with Section 11B-302. Access aisles shall be at the same level as the vehicle pull-up space they serve....
-
11B-503.4 Floor and ground surfaces
Vehicle pull-up spaces and access aisles serving them shall comply with Section 11B-302. Access aisles shall be at the same level as the vehicle pull-up space they serve....
-
503.4 Floor and Ground Surfaces
Vehicle pull-up spaces and access aisles serving them shall comply with 302. Access aisles shall be at the same level as the vehicle pull-up space they serve....
-
503.4 Floor and Ground Surfaces
Vehicle pull-up spaces and access aisles serving them shall comply with 302. Access aisles shall be at the same level as the vehicle pull-up space they serve....
-
1012 Parking Spaces Within Camping Units and Picnic Units and Pull-Up Spaces at Dump Stations
[See subsections ...]
-
§ 38.159(b)(6) Platform surface
(6) Platform surface. The platform surface shall be free of any protrusions of 1/4 inch (6.5 mm) high and shall be slip resistant. The platform shall have a minimum clear width of 28...
-
§ 38.159(c)(2) Ramp surface
(2) Ramp surface. The ramp surface shall be continuous and slip resistant; shall not have protrusions from the surface greater than 1/4 inch (6.5 mm) high; shall have a clear width...
-
§ 38.83(b)(6) Platform surface
(6) Platform surface. The lift platform surface shall be free of any protrusions over 1/4 inch high and shall be slip resistant. The lift platform shall have a minimum clear width of...
-
11B-503.5 Vertical clearance
Vehicle pull-up spaces, access aisles serving them, and a vehicular route from an entrance to the passenger loading zone and from the passenger loading zone to a vehicular exit shall provide...