The height of the transfer wall shall be 16 inches (406 mm) minimum and 19 inches (483 mm) maximum measured from the deck....
Search Results "Transfer Position"
Commonly Searched Documents
-
11B-1009.4.2 Height
-
11B-1009.4.2 Height
The height of the transfer wall shall be 16 inches (406 mm) minimum and 19 inches (483 mm) maximum measured from the deck....
-
M301 Diagnostic Equipment Used by Patients in Supine, Prone, or Side-Lying Position
[See subsections ...]
-
M301 Diagnostic Equipment Used by Patients in Supine, Prone, or Side-Lying Position
[See subsections ...]
-
Surface
Surface Since people using transfer walls are in bathing suits, their skin may be in contact with the wall....
-
M301.1 General
Where diagnostic equipment is used by patients in a supine, prone, or side-lying position, it shall comply with M301....
-
Clear Deck Space: ADA Standard Section 1009.4.1
A clear deck space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
11B-1009.4.1 Clear deck space
A clear deck space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (355 mm) minimum and 17 inches (430 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum. ...
-
11B-1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (356 mm) minimum and 17 inches (432 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum....
-
11B-1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (356 mm) minimum and 17 inches (432 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum....
-
Chapter 1: Background
space (length/width) needed to position the wheelchair in proximity to the target....
-
M304.1 General (Section-by-Section Analysis)
This is an introductory section.
-
ii. Accessible scales
ii. Accessible scales Medical providers often do not weigh individuals who use wheelchairs because they do not have an accessible scale, even though that information is a routine...
-
M302 Diagnostic Equipment Used by Patients in Seated Position
[See subsections ...]
-
M302 Diagnostic Equipment Used by Patients in Seated Position
[See subsections ...]
-
Standing Supports (M304.3 and M305.3)
Standing supports can be provided in a horizontal position, vertical position, or a combination of horizontal and vertical positions, as long as the minimum length of gripping surface is...
-
11B-407.4.8 Car position indicators
Audible and visible car position indicators shall be provided in elevator cars....
-
11B-407.4.8 Car position indicators
Audible and visible car position indicators shall be provided in elevator cars....
-
11B-407.4.8 Car position indicators
Audible and visible car position indicators shall be provided in elevator cars....
-
Overhead Lifts
The technical criteria do not address overhead lifts that are usually mounted on the ceiling and operate on tracks suspended over the diagnostic equipment because the configuration...
-
Clearance in Base (M301.4.1 and M302.4.1)
Clearance in the base of the equipment allows the legs of a portable floor lift to fit under the base of the equipment. The clearance can be an open area between the supporting posts...
-
11B-1008.2.4.2 Elevated
The clear width of transfer systems connecting elevated play components shall be permitted to be 24 inches (610 mm) minimum....
-
Elevated: ADA Standard Section 1008.2.4.2
The clear width of transfer systems connecting elevated play components shall be permitted to be 24 inches (610 mm) minimum....