Transfer devices for use with amusement rides shall comply with 1002.6 when positioned for loading and unloading. Advisory 1002.6 Transfer Devices for Use with Amusement Rides....
Search Results "Transfer Position"
-
1002.6 Transfer Devices for Use with Amusement Rides
-
1002.6 Transfer Devices for Use with Amusement Rides
Transfer devices for use with amusement rides shall comply with 1002.6 when positioned for loading and unloading. Advisory 1002.6 Transfer Devices for Use with Amusement Rides....
-
Armrests M302.3.2
If provided armrests cannot interfere with transfer supports during the transfer....
-
5.4.11 Transfer Support Structural Strength Recommendations for M301 and M302
5.4.11 Transfer Support Structural Strength Recommendations for M301 and M302 Description: Transfer supports and their connections must be capable of resisting sufficient vertical and...
-
Preferred Seat Widths
The seat width percentiles remained the same for transfers to and from the station and within each protocol....
-
608.2.1 Transfer Type Shower Compartments
Transfer type shower compartments shall be 36 inches (915 mm) by 36 inches (915 mm) clear inside dimensions measured at the center points of opposing sides and shall have a 36 inch (915...
-
11B-1009.5.7 Grab bars
At least one grab bar on each transfer step and the transfer platform or a continuous grab bar serving each transfer step and the transfer platform shall be provided....
-
11B-1009.5.7 Grab bars
At least one grab bar on each transfer step and the transfer platform or a continuous grab bar serving each transfer step and the transfer platform shall be provided....
-
Grab Bars: ADA Standard Section 1009.5.7
At least one grab bar on each transfer step and the transfer platform or a continuous grab bar serving each transfer step and the transfer platform shall be provided....
-
Additional Transfer Techniques: Use of Stretchers and Gurneys
Other equipment may be located in spaces with no room at the end of the table making it impossible to position a portable floor lift....
-
Stirrups (M301.3.2)
Where stirrups are provided on diagnostic equipment used by patients in a supine, prone, or side-lying position, M301.3.2 would require the stirrups to provide a method of supporting, positioning...
-
Entry Points and Seats: ADA Standard Section 1008.4.4
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (280 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
Shooting Facilities
Shooting Facilities If facilities provide fixed firing positions, at least 5 percent, but not less than one of each type of fixed firing position must be served by an accessible route...
-
11B-1002.6 Transfer devices for use with amusement rides
Transfer devices for use with amusement rides shall comply with Section 11B-1002.6 when positioned for loading and unloading....
-
11B-1002.6 Transfer devices for use with amusement rides
Transfer devices for use with amusement rides shall comply with Section 11B-1002.6 when positioned for loading and unloading....
-
11B-1002.6 Transfer devices for use with amusement rides
Transfer devices for use with amusement rides shall comply with Section 11B-1002.6 when positioned for loading and unloading....
-
11B-1008.4.4 Entry points and seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (279 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
11B-1008.4.4 Entry points and seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (279 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
Initial Measures and Transfer Setup
However, for the setup of the baseline level transfer (when the person and mobility device were in a position next to platform ready to transfer), if there was a noticeable difference (one...
- Figure 1009.5.1 Size of Transfer Platform – Drawing from the U.S. Access Board
-
5. Exception from the Requirements of M302 for Weight Scales with Integral Seats
The MDE NPRM proposed that diagnostic equipment which could be used by patients in multiple positions must comply with the technical criteria for all positions in which it could be used...
-
4. Organization of Technical Criteria
each of the patient positions; and the types of equipment to which the technical criteria apply for each of the patient positions....
-
M301.1 General (Section-by-Section Analysis)
The MDE NPRM proposed that all diagnostic equipment used by patients in a supine, prone, or side-lying position must comply with the technical requirements of proposed section M301....
-
F243.1 General
Where shooting facilities with firing positions are designed and constructed at a site, at least 5 percent, but no fewer than one, of each type of firing position shall comply with 1010....