Section 307.3 covers the current ADA Standards for the protrusion limits for post-mounted objects.
Search Results "Non-Glare Finish"
-
Post-Mounted Objects: ADA Standard Section 307.3
-
11B-307.3 Post-mounted objects
Free-standing objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (686 mm) minimum and 80 inches (2032 mm) maximum above the finish...
-
11B-812.8.7 Location
Signs shall be 60 inches (1525 mm) minimum above the finish floor or ground surface measured to the bottom of the sign....
-
11B-812.8.7 Location
Signs shall be 60 inches (1525 mm) minimum above the finish floor or ground surface measured to the bottom of the sign....
-
11B-307.3 Post-mounted objects
Free-standing objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (686 mm) minimum and 80 inches (2032 mm) maximum above the finish...
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor....
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor....
-
Drinking Fountains for Standing Persons: ADA Standard Section 602.7
Section 602.7 covers the current ADA Standards for drinking fountains for standing persons.
-
11B-602.7 Drinking fountains for standing persons
Spout outlets of drinking fountains for standing persons shall be 38 inches (965 mm) minimum and 43 inches (1092 mm) maximum above the finish floor or ground....
-
Height: ADA Standard Section 407.3.3.1
Section 407.3.3.1 covers the current ADA Standards for the height requirements of an elevators reopening device.
-
11B-809.10.7.5 Controls
Controls shall be mounted 44 inches (1118 mm) maximum above the finish floor. The force required to activate controls shall be 5 pounds (22.2 mm) maximum....
-
11B-809.10.7.5 Controls
Controls shall be mounted 44 inches (1118 mm) maximum above the finish floor. The force required to activate controls shall be 5 pounds (22.2 mm) maximum....
-
11B-602.7 Drinking fountains for standing persons
Spout outlets of drinking fountains for standing persons shall be 38 inches (965 mm) minimum and 43 inches (1092 mm) maximum above the finish floor or ground....
-
203.9 Employee Work Areas
Employee work areas, or portions of employee work areas, other than raised courtroom stations, that are less than 300 square feet (28 m2) and elevated 7 inches (180 mm) or more above the finish...
-
General: ADA Standard Section 306.3.1
Section 306.3.1 of the ADA Standards covers information in the current ADA Standards for knee clearance.
-
11B-813.2.6 Shelf
No fewer than one shelf shall be provided in close proximity to the changing table at 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor....
-
11B-813.2.6 Shelf
No fewer than one shelf shall be provided in close proximity to the changing table at 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor....
-
11B-411.4.6.2 Buttons
The car shall not have non-functional, exposed floor buttons....
-
11B-411.4.6.2 Buttons
The car shall not have non-functional, exposed floor buttons....
-
11B-306.2.4 Additional clearance
Space extending greater than 6 inches (152 mm) beyond the available knee clearance at 9 inches (229 mm) above the finish floor or ground shall not be considered toe clearance....
-
Additional Clearance: ADA Standard Section 306.2.4
Section 306.2.4 covers the current ADA Standards for additional clearances for toe space.
-
11B-306.2.4 Additional clearance
Space extending greater than 6 inches (152 mm) beyond the available knee clearance at 9 inches (229 mm) above the finish floor or ground shall not be considered toe clearance....
- Otis Elevator Advanced Lantern Retrofit
-
11B-225.2.3 Library book stacks
Book stacks available for public use shall be 54 inches (1372 mm) maximum above the finish floor....