permitted under sinks and work surfaces provided that all of the following conditions are met: a) base cabinets can be removed without the use of specialized tools or knowledge; b) the finish...
Search Results "Non-Glare Finish"
-
11B-809.9.3 Removable base cabinets
-
11B-307.4 Vertical clearance
The leading edge of such guardrail or barrier shall be located 27 inches (686 mm) maximum above the finish floor or ground....
-
Location: ADA Standard Section 407.4.6.1
Section 407.4.6.1 covers the current ADA Standards for the location of elevator car controls.
-
11B-407.4.6.1 Location
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm) maximum above the finish...
-
11B-605.5.4 Toe Clearance
The front partition and at least one side partition shall provide a toe clearance of 9 inches (229 mm) minimum above the finish floor and 6 inches (152 mm) deep minimum beyond the compartment-side...
-
11B-605.5.4 Toe Clearance
The front partition and at least one side partition shall provide a toe clearance of 9 inches (229 mm) minimum above the finish floor and 6 inches (152 mm) deep minimum beyond the compartment-side...
-
11B-407.4.6.1 Location
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm) maximum above the finish...
-
Parallel Approach: ADA Standard Section 904.4.1
A portion of the counter surface that is 36 inches (915 mm) long minimum and 36 inches (915 mm) high maximum above the finish floor shall be provided....
-
Clear Floor or Ground Space: ADA Standard Section 804.3.1
the kitchen work surface provided that all of the following conditions are met: (a) the cabinetry can be removed without removal or replacement of the kitchen work surface; (b) the finish...
-
Error/Omission: The shape of the door hardware requires tight grasping, pinching, and twisting of the wrist to use.
Hardware required for accessible door passage shall be mounted no higher than 48 in (1220 mm) above finished floor....
-
Circulation Paths
Objects projecting from walls (for example, telephones) with their leading edges between 27 in and 80 in (685mm and 2030 mm) above the finished floor shall protrude no more than 4 in (100...
-
Clear Width: ADA Standard Section 404.2.3
Section 404.2.3 covers the current ADA Standards for clear width at manual doors, doorways and manual gates that are part of an accessible route.
-
11B-404.2.3 Clear width
There shall be no projections into the required clear opening width lower than 34 inches (864 mm) above the finish floor or ground....
-
11B-404.2.3 Clear width
There shall be no projections into the required clear opening width lower than 34 inches (864 mm) above the finish floor or ground....
-
Spout Height: ADA Standard Section 602.4
Section 602.4 covers the current ADA Standards for the spout height of drinking fountains.
-
11B-602.4 Spout height
Spout outlets shall be 36 inches (914 mm) maximum above the finish floor or ground....
-
11B-602.4 Spout height
Spout outlets shall be 36 inches (914 mm) maximum above the finish floor or ground....
-
11B-411.2.1.3.4 Position
Display screens and touch screens shall be positioned so glare is reduced on the screen....
-
Position of Grab Bars: ADA Standard Section 609.4
Section 609.4 covers the current ADA Standards for the position of grab bars.
-
11B-804.3.1 Clear floor or ground space
work surface provided that all of the following conditions are met: (a) the cabinetry can be removed without removal or replacement of the kitchen work surface; (b) the finish...
-
11B-804.3.1 Clear floor or ground space
work surface provided that all of the following conditions are met: (a) the cabinetry can be removed without removal or replacement of the kitchen work surface; (b) the finish...
-
Clear Floor Space: ADA Standard Section 606.2
Section 606.2 covers the current ADA Standards for clear floor space at lavatories and sinks.
-
11B-604.8.1.4 Toe clearance
At least one side partition shall provide a toe clearance of 9 inches (229 mm) minimum above the finish floor and 6 inches (152 mm) deep minimum beyond the compartment-side face of the partition...
-
11B-604.8.1.4 Toe clearance
At least one side partition shall provide a toe clearance of 9 inches (229 mm) minimum above the finish floor and 6 inches (152 mm) deep minimum beyond the compartment-side face of the partition...