They shall adjoin an accessible route that also serves as a means of egress in case of emergency and shall be located to provide lines of sight comparable to those for all viewing areas....
Search Results "Means of Entry"
Commonly Searched Documents
-
4.33.3* PLACEMENT OF WHEELCHAIR LOCATIONS
-
General
The 1991 Standards at sections 4.1.3(9); 4.1.6(1)(g); and 4.3.10 establish scoping and technical requirements for accessible means of egress....
-
§ 36.303(g)(6) Alternative technologies
(6) Alternative technologies.
-
A4.3.11.3 Stairway Width
A 48 in (1220 mm) wide exit stairway is needed to allow assisted evacuation (e.g., carrying a person in a wheelchair) without encroaching on the exit path for ambulatory persons.
-
1007.2.1 Buildings with four or more stories
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, at least one required accessible means of egress shall be an elevator complying...
-
1003.2.13.1.1 Buildings with four or more stories
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, at least one required accessible means of egress shall be an elevator complying...
-
Portable ramp - step 6 inches or less
[See subsections ...]
-
2. Standing Supports
supports, be integrated into the platform, and be a minimum of 32 inches in length (at least 80 percent of the platform length) at the platform entry edge....
-
5. Edge Protection
The Advisory Committee made two recommendations for requiring edge protection on raised platforms; for single ramped entry platforms, the Committee recommended requiring a minimum two-inch...
-
M303.3.3 Ramped (Section-by-Section Analysis)
The MDE NPRM proposed that for equipment with a change in level at the entry of a wheelchair space, level changes greater than ½ inch high would be required to be ramped and comply with...
-
1009.4 Elevators
In order to be considered part of an accessible means of egress, an elevator shall comply with the emergency operation and signaling device requirements of California Code of Regulations...
- SafePath EntryLevel™ Landings
-
1007.4 Elevators
In order to be considered part of an accessible means of egress, an elevator shall comply with the emergency operation and signaling device requirements of California Code of Regulations...
-
1007.8.2 Exterior exit stairway
Exterior exit stairways that are part of the means of egress for the exterior area for assisted rescue shall provide a clear width of 48 inches (1219 mm) between handrails....
-
1010.1.7 Thresholds
The door is not part of the required means of egress. 1.2. The door is not part of an accessible route as required by Chapter 11A or 11B. 1.3....
-
1011.4, Item 3
Each exit door that is required to comply with Section 1011.1, and that leads directly to a grade-level exterior exit by means of an exit enclosure or an exit passageway shall be identified...
-
1013.4, Item 3
Each exit door that is required to comply with Section 1013.1, and that leads directly to a grade-level exterior exit by means of an exit enclosure or an exit passageway shall be identified...
-
1010.1.9.8.1 Delayed egress locking system
Once the delay electronics have been deactivated, rearming the delay electronics shall be by manual means only....
-
207.1 General
Means of egress shall comply with section 1003.2.13 of the International Building Code (2000 edition and 2001 Supplement) or section 1007 of the International Building Code (2003 edition...
-
1007.7.2 Outdoor facilities
Every required exterior area of assisted rescue shall have direct access to an interior exit stairway, exterior stairway, or elevator serving as an accessible means of egress component....
-
1010.1.9.7 Delayed egress locks
Once the delay electronics have been deactivated, rearming the delay electronics shall be by manual means only....
-
M303.3.3.3 Clear Width
The clear width of ramp runs shall be 36 inches (915 mm) minimum.
-
M303.3.3.1 Running Slope
Ramp runs shall have a running slope not steeper than 1:12. EXCEPTION: A running slope not steeper than 1:8 shall be permitted for ramp runs with a maximum height of 2 ½ inches...
-
M303.3.3.4 Edge Protection
Ramps with drop offs ½ inch (13 mm) or greater shall provide edge protection 2 inches (50 mm) high minimum on each side with a drop off.