Required guards shall not be less than 42 inches (1067 mm) high, measured vertically as follows: From the adjacent walking surfaces. On stairways and stepped aisles, from the...
Search Results "Means of Entry"
Commonly Searched Documents
-
1015.3 Height
-
1011.5.2 Riser height and tread depth
... Exceptions: 4. See California Fire Code Chapter 11 and California Existing Building Code for the replacement of existing stairways. [DSA-AC] For applications listed in...
-
1009.8.2 Directions
Directions for the use of the two-way communication system, instructions for summoning assistance via the two-way communication system and written identification of the location...
-
1010.1.8 Door arrangement
Space between two doors in a series shall be 48 inches (1219 mm) minimum plus the width of a door swinging into the space. Doors in a series shall swing either in the same direction...
-
1018.3 Aisles in Groups B and M
In Group B and M occupancies, the minimum clear aisle width shall be determined by Section 1005.1 for the occupant load served, but shall be not less than that required for corridors...
-
1018.5 Aisles in other than assembly spaces and Groups B and M
In other than rooms or spaces used for assembly purposes and Group B and M occupancies, the minimum clear aisle capacity shall be determined by Section 1005.1 for the occupant load...
-
1007.6.4 Instructions
The instructions shall include all of the following: Directions to find other means of egress....
-
1003.2.13.5.4 Instructions
Directions to find other means of egress. 2. Persons able to use the exit stairway do so as soon as possible, unless they are assisting others. 3....
-
11B-207.1 General
Means of egress shall comply with Chapter 10, Section 1007. [2010 ADAS] 207.1 General....
-
11B-207.1 General
Means of egress shall comply with Chapter 10, Section 1009. [2010 ADAS] 207.1 General....
-
11B-207.1 General
Means of egress shall comply with Chapter 10, Section 1009. [2010 ADA Standards] 207.1 General....
-
1009.12 Alarms/emergency warning systems/accessibility
If emergency warning systems are required, they shall activate a means of warning the hearing impaired....
-
1009.12 Alarms/emergency warning systems/accessibility
If emergency warning systems are required, they shall activate a means of warning the hearing impaired....
-
Wedges
[See subsections ...]
-
Section H: Lifts
Ward:__________ Precinct:__________ Staff:_______________ Date:_________ Time:_________ Address:_______________________________________ Location...
-
1007.12 Alarms/emergency warning systems/accessibility
If emergency warning systems are required, they shall activate a means of warning the hearing impaired....
- SafePath: Threshold Ramp Installation for MultiFamily Housing for Disability Access
-
EZ-ACCESS® Incline Calculator for Ramp Solutions
EZ-ACCESS® Incline Calculator [Click here to access the online calculator] To Establish the Proper Ramp Length: Determine the incline that your chair is designed to...
-
Required Compliance [§210]
Required Compliance [§210] Interior and exterior stairs that are part of a required means of egress must meet the Standards....
-
11B-210.1 General
Interior and exterior stairs that are part of a means of egress shall comply with 504. Exceptions: 1....
-
1007.6.1 Size
Such wheelchair spaces shall not reduce the required means of egress width....
-
1009.6.3 Size
Such wheelchair spaces shall not reduce the means of egress minimum width or required capacity....
-
1009.6.3 Size
Such wheelchair spaces shall not reduce the means of egress minimum width or required capacity....
-
General: ADA Standard Section 210.1
Section 210.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for stairways.