407.2.2.2 Visible Signals. Visible signal fixtures shall be centered at 72 inches (1830 mm) minimum above the finish floor or ground. The visible signal elements shall be 2½ inches...
Search Results "Level Landing"
Commonly Searched Documents
- 
    
  
  407.2.2.2 Visible Signals
  
- 
    
  
  4.10.4 Hall Lanterns
  A visible and audible signal shall be provided at each hoistway entrance to indicate which car is answering a call. Audible signals shall sound once for the up direction and twice... 
- 
    
  
  11B-407.2.2.1 Visible and audible signals
  A visible and audible signal shall be provided at each hoistway entrance to indicate which car is answering a call and the car’s direction of travel. Where in-car signals are... 
- 
    
  
  11B-407.2.2.1 Visible and audible signals
  A visible and audible signal shall be provided at each hoistway entrance to indicate which car is answering a call and the car’s direction of travel. Where in-car signals are... 
- 
    
  
  DSA Drawing 11B-406-3 Perpendicular Curb Ramp next to a Curb and Gutter (2016 CBC)
  Requires the Premium User plan or above. (Login or upgrade your account!)
- 
    
  
  1132A.4 Level floor or landing
  The floor or landing on each side of a door shall be level.... 
- 
    
  
  § 35.150(b)(4)(i)
  (i) In addition to the provisions of section 240.2.1 of the proposed standards, where an existing play area provides elevated play components, an additional number of ground level play components... 
- 
    
  
  Accessible Route to Play Components
  Section 206.2.17 of the 2010 Standards provides scoping requirements for accessible routes to ground level and elevated play components and to soft contained play structures.... 
- 
    
  
  § 38.125(c)(3) Ramp threshold
  Changes in level between 1/4 inch and 1/2 inch shall be beveled with a slope no greater than 1:2.... 
- 
    
  
  § 38.95(c)(3) Ramp threshold
  Changes in level between 1/4 inch and 1/2 inch shall be beveled with a slope no greater than 1:2.... 
- 
    
  
  M303.3 Entry
  Where there is a change in level at the entry to wheelchair spaces, the change in level shall comply with M303.3.... 
- 
    
  
  M303.3 Entry
  Where there is a change in level at the entry to a wheelchair space, the change in level shall comply with M303.3.... 
- 
    
  
  § 38.95(a)(2) Exception
  If level-entry boarding, portable or platform lifts, ramps or bridge plates meeting the applicable requirements of this section are provided on station platforms or other stops required... 
- 
    
  
  § 38.83(b)(8) Platform entrance ramp
  The entrance ramp, or loading-edge barrier used as a ramp, shall not exceed a slope of 1:8 measured on level ground, for a maximum rise of 3 inches, and the transition from the station platform... 
- 
    
  
  § 38.159(b)(8) Platform entrance ramp
  The entrance ramp, or loading-edge barrier used as a ramp, shall not exceed a slope of 1:8, measured on level ground, for a maximum rise of 3 inches (75 mm), and the transition from roadway... 
- 
    
  
  404.2.4.4 Floor or Ground Surface
  Changes in level are not permitted. EXCEPTIONS: 1. Slopes not steeper than 1:48 shall be permitted. 2. Changes in level at thresholds complying with 404.2.5 shall be permitted.... 
- 
    
  
  404.2.4.4 Floor or Ground Surface
  Changes in level are not permitted. EXCEPTIONS: 1. Slopes not steeper than 1:48 shall be permitted. 2.... 
- 
    
  
  404.2.4.4 Floor or Ground Surface
  Changes in level are not permitted. EXCEPTIONS: 1. Slopes not steeper than 1:48 shall be permitted. 2. Changes in level at thresholds complying with 404.2.5 shall be permitted.... 
- 
    
  
  11B-404.2.4.4 Floor or ground surface
  Changes in level are not permitted. Exceptions: 1. Slopes not steeper than 1:48 shall be permitted. 2. ... 
- 
    
  
  11B-404.2.4.4 Floor or ground surface
  Changes in level are not permitted. Exceptions: 1. Slopes not steeper than 1:48 shall be permitted. 2.... 
- 
    
  
  Play areas. (Section-by-Section Analysis)
  Section 240.2.1.1 of the 2004 ADAAG requires that at least one ground level play component of each type provided (e.g., for different experiences such as rocking, swinging, climbing, spinning... 
- 
    
  
  4.1.3(1) ELEVATORS
  Elevators or other accessible means of vertical movement are not required in residential facilities when: (a) No accessible dwelling units are located above or below the accessible grade level... 
- 
    
  
  11B-240.2.1.2 Additional number and types
  Where elevated play components are provided, ground level play components shall be provided in accordance with Table 11B-240.2.1.2 and shall comply with Section 11B-1008.4.... 