Changes in level are not permitted. Exception:  Slopes not steeper than 1:48 shall be permitted. [2010 ADAS] Advisory 304.2 Floor or Ground Surfaces Exception. ...
Search Results "Level Landing"
Commonly Searched Documents
-
11B-304.2 Floor or Ground Surfaces
-
11B-304.2 Floor or ground surfaces
Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. Exception: Reserved. Advisory 11B-304.2 Floor or ground surface Exception....
-
Maneuvering Space
At least one maneuvering space must be provided on the same level as elevated play components....
-
1132A.4 Level floor or landing
1132A.4 Level floor or landing. See also Chapter 10. The floor or landing on each side of a door shall be level....
-
11B-504.4 Tread surface
Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. Exception: Reserved....
- How To Calibrate a Digital Slope Meter
-
407.2.2.2 Visible Signals
Visible signal fixtures shall be centered at 72 inches (1830 mm) minimum above the finish floor or ground. The visible signal elements shall be 2½ inches (64 mm) minimum measured...
-
11B-407.2.2.1 Visible and audible signals
A visible and audible signal shall be provided at each hoistway entrance to indicate which car is answering a call and the car’s direction of travel. Where in-car signals are...
-
407.2.2.2 Visible Signals
Visible signal fixtures shall be centered at 72 inches (1830 mm) minimum above the finish floor or ground. The visible signal elements shall be 2 1/2 inches (64 mm) minimum measured...
-
407.2.2.2 Visible Signals
407.2.2.2 Visible Signals. Visible signal fixtures shall be centered at 72 inches (1830 mm) minimum above the finish floor or ground. The visible signal elements shall be 2½ inches...
-
4.10.4 Hall Lanterns
A visible and audible signal shall be provided at each hoistway entrance to indicate which car is answering a call. Audible signals shall sound once for the up direction and twice...
-
11B-407.2.2.1 Visible and audible signals
A visible and audible signal shall be provided at each hoistway entrance to indicate which car is answering a call and the car’s direction of travel. Where in-car signals are...
-
11B-407.2.2.1 Visible and audible signals
A visible and audible signal shall be provided at each hoistway entrance to indicate which car is answering a call and the car’s direction of travel. Where in-car signals are...
-
DSA Drawing 11B-406-3 Perpendicular Curb Ramp next to a Curb and Gutter (2016 CBC)
Requires the Premium User plan or above. (Login or upgrade your account!)
-
1132A.4 Level floor or landing
The floor or landing on each side of a door shall be level....
-
§ 35.150(b)(4)(i)
(i) In addition to the provisions of section 240.2.1 of the proposed standards, where an existing play area provides elevated play components, an additional number of ground level play components...
- PEMKO 2 1/2" Saddle Threshold No. 166
- PEMKO 5" Latching Panic Saddle Threshold No. 2705-T
- PEMKO 7" Saddle Threshold No. 176
- PEMKO 5" Latching Panic Saddle Threshold No. 2006-P
- PEMKO 5" Latching Panic Saddle Threshold No. 2005-P
- PEMKO 5 1/8" Thermal Barrier Threshold No. 252X3-FG