Changes in level between 1/4 inch (6.5 mm) and 1/2 inch (13 mm) shall be beveled with a slope no greater than 1:2....
Search Results "Grade Level Exit"
Commonly Searched Documents
-
§ 38.159(c)(3) Ramp threshold
-
407.2.3.1 Floor Designation
A tactile star shall be provided on both jambs at the main entry level....
-
7.4.6 Tread Obstacles
Tread obstacles on trails shall not exceed 2 inches (50 mm) in height measured vertically to the highest point. Where the trail surface is paved or is elevated above the natural...
-
A4.28.2 Audible Alarms
Audible emergency signals must have an intensity and frequency that can attract the attention of individuals who have partial hearing loss. People over 60 years of age generally have...
-
A4.28.2 AUDIBLE ALARMS
Audible emergency signals must have an intensity and frequency that can attract the attention of individuals who have partial hearing loss. People over 60 years of age generally have...
-
Wet Conditions [§405.10]
Wet Conditions [§405.10] Landings subject to wet conditions must be designed to prevent the accumulation of water. Landings are permitted slopes not steeper than 1:48 to allow for...
-
1131A.2 Changes greater than ½ inch
Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units horizontal (5-percent slope), or a ramp, elevator or...
-
504.4 Tread Surface
Changes in level are not permitted. EXCEPTION: Treads shall be permitted to have a slope not steeper than 1:48. Advisory 504.4 Tread Surface....
-
703.4.1 Height Above Finish Floor or Ground
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60...
-
Are stairs in residential dwelling units covered by the Standards required to comply?
Yes, stairs that are part of a means of egress must comply in mobility accessible residential dwelling units covered by the Standards. Egress stairs of residential facilities that...
-
11B-703.4.2 Location
Where provided, signs identifying exits shall be located at the exit door when approached in the direction of egress travel. [2010 ADA Standards] 703.4.2 Location....
-
207 Accessible Means of Egress
Where a required exit from an occupiable level above or below a level of accessible exit discharge is not accessible, an area of rescue assistance shall be provided on each such level (in...
- PEMKO 2" to 48" Aluminum Plates No. 14/1
- PEMKO 5 29/32" Floor Plates/Safety Treads No. 2266
- PEMKO 9 1/2" Floor Plates/Safety Treads No. 2286
- PEMKO 6-1/8" Floor Plates/Safety Treads No.19325
- PEMKO 3" Floor Plates/Safety Treads No. 19125
- PEMKO 8" Floor Plates/Safety Treads No. 228
- PEMKO 6 1/8" Floor Plates/Safety Treads No. 193
- PEMKO 3" Floor Plates/Safety Treads No. 191
- PEMKO 2" Floor Plates/Safety Treads No. 190
- PEMKO 2" Floor Plates/Safety Treads No. 190B
- PEMKO 2" Floor Plates/Safety Treads No. E197
- PEMKO 3" Floor Plates/Safety Treads No. 200