Protruding objects shall not reduce the clear width of an accessible route or maneuvering space (see Fig. 8(e))....
Search Results "Clear Width at Turn"
Commonly Searched Documents
-
4.4.1* General
-
8.4 Card Catalogs and Magazine Displays
Minimum clear aisle space at card catalogs and magazine displays shall comply with Fig. 55....
-
8.4 CARD CATALOGS
Minimum clear aisle space at card catalogs, magazine displays, or reference stacks shall comply with Fig. 55....
-
9.5.2(2)(a)
(a) at least one public entrance shall allow a person with mobility impairments to approach, enter and exit including a minimum clear door width of 32 in (815 mm)....
-
4.4.1* GENERAL
Protruding objects shall not reduce the clear width of an accessible route or maneuvering space (see Fig. 8(e)). Figure 8 Protruding Objects...
-
7.3 CHECK-OUT AISLES
Clear aisle width shall comply with 4.2.1 and maximum adjoining counter height shall not exceed 36 in (915 mm) above the floor....
-
406.4 Landings
The landing clear length shall be 36 inches (915 mm) minimum. The landing clear width shall be at least as wide as the curb ramp, excluding flared sides, leading to the landing....
-
Measuring Door Openings
Special care is needed when measuring the clear opening of a doorway. To measure the clear opening of a standard hinged door, open the door to 90 degrees....
-
(1)(e)
(e) Doorways on the end of the enclosure, opposite the water closet, should have a minimum clear opening width of 32 inches (815 mm)....
-
9.5.2(2)(c)
(c) at least one toilet room for each gender or one unisex toilet room shall have a minimum clear door width of 32 in (815 mm), minimum turning space complying with 4.2.3, one water closet...
-
§ 38.23(c)(2) Ramp surface
The ramp surface shall be continuous and slip resistant; shall not have protrusions from the surface greater than 1/4 inch high; shall have a clear width of 30 inches; and shall accommodate...
-
§ 38.83(c)(2) Ramp surface
The ramp or bridge plate surface shall be continuous and slip resistant, shall not have protrusions from the surface greater then 1/4 inch, shall have a clear width of 30 inches, and shall...
-
406.4 Landings
The landing clear length shall be 36 inches (915 mm) minimum. The landing clear width shall be at least as wide as the curb ramp, excluding flared sides, leading to the landing....
-
304.3.2 T-Shaped Space
The turning space shall be a T-shaped space within a 60 inch (1525 mm) square minimum with arms and base 36 inches (915 mm) wide minimum....
-
1017.2 Aisles in assembly spaces
1017.2 Aisles in assembly spaces. Aisles and aisle accessways serving a room or space used for assembly purposes shall comply with Section 1028.
-
N1
N1. Is there an accessible route, at least 36 inches wide, that connects each of the shelter activity areas with the health units and medical care areas (it may narrow to 32 inches...
-
K2
K2. Is there an accessible route that is at least 36 inches wide that connects accessible tables with serving, condiment, and dispenser areas? [ADA Standards § 5.3;...
-
§ 36.304(b)(8)
(8) Widening doors;
-
Sec.36.304(b)(8)
(8) Widening doors;
-
4.1.6(4)(d)
(d) Doors. (i) Where existing elements prohibit strict compliance with the clearance requirements of 4.13.5, a projection of 5/8 in (16 mm) maximum will be permitted for the latch...
-
§100.205(c)(2)
(2) All the doors designed to allow passage into and within all premises are sufficiently wide to allow passage by handicapped persons in wheelchairs; and
-
§ 38.153(c)
(c)
-
4.35.2 Clear Floor Space
A clear floor space allowing a person using a wheelchair to make a 180-degree turn shall be provided in every accessible dressing room entered through a swinging or sliding door....
-
11B-1008.4.2 Clear floor or ground space
Clear floor or ground space complying with Sections 11B-305.2 and 11B-305.3 shall be provided at play components. Advisory 11B-1008.4.2 Clear floor or ground space....