Generator and transformer rooms separated from the remainder of the building by walls and floor/ceiling or roof/ceiling assemblies having a fire-resistance rating of not less than 2 hours...
Search Results "Floor Surface"
Commonly Searched Documents
-
903.3.1.1.1 Exempt locations
-
Determine Your Evacuation Options When Traveling
When staying in hotels/motels/cruise ships and other lodging facilities: When you have a choice, do you think about whether you want the view or the safety of a lower floor?...
-
11B-220.1.2 Two automatic teller machines or fare machines
or fare machines are provided at a location, one shall comply with Sections 11B-707.2 through 11B-707.8 and one shall comply with Sections 11B-309 _|Operable Parts|_, 11B-707.2 _|Clear Floor...
-
4.1.6(3)(e)(i)
(i) Where it is technically infeasible to comply with 4.22 or 4.23, the installation of at least one unisex toilet/bathroom per floor, located in the same area as existing toilet facilities...
-
Disability Discrimination
Disability Discrimination Authorities on disability have often said, and I have quoted them on this floor before, that the history of society’s formal methods of dealing with people with...
-
4.1.6(3)(c)
(ii) At least one toilet facility for each sex on each substantially altered floor, where such facilities are provided, complying with 4.22, Toilet Rooms; and 4.23, Bathrooms, Bathing Facilities...
-
III-5.4300 Transportation terminals
services in a two-story facility - including boarding, debarking, loading and unloading, baggage claim, dining facilities, and other common areas open to the public - are located on the same floor...
-
1132A.4.1 Thresholds
., floor material changes at door thresholds) shall not exceed ½ inch (12.7 mm). Thresholds shall comply with the following:...
-
11B-605.4 Flush controls
Hand operated flush controls shall comply with Section 11B-309 except that the flush control shall be mounted at a maximum height of 44 inches (1118 mm) above the finish floor....
-
11B-809.10.8.1 Location
The top of the lavatory rim shall be 34 inches (864 mm) maximum above the finished floor....
-
Appendix A: Pedestrians with Visual Impairments
the two surfaces....
- Guldmann Basic High Sling - Kids
-
Islands: ADA Standard Section 406.7
Section 406.7 covers the current ADA Standards for islands.
-
ACCESSIBLE DWELLING UNITS
Requires the Accessibility Specialist plan or above. (Login or upgrade your account!)
-
TABLE OF CONTENTS
in private residences 11B-246 Outdoor developed areas 11B-247 Detectable warnings and detectable directional texture DIVISION 3: BUILDING BLOCKS 11B-301 General 11B-302 Floor...
-
1132A.4.1 Thresholds
., floor material changes at door thresholds) shall not exceed ½ inch (12.7 mm). Thresholds shall comply with the following:...
-
607 Bathtubs
Specifications for bathtubs in section 607 address clear floor space, seats, grab bars, operable parts, shower spray units, and enclosures....
-
Saunas and Steam Rooms
Doors cannot swing into any part of the clear floor or ground space required for benches....
-
Exercise machines. (Section-by-Section Analysis)
Sections 206.2.13 and 236 of the 2004 ADAAG require one of each type of fixed exercise machine to meet clear floor space specifications and to be on an accessible route. ...
-
Exercise machines. (Section-by-Section Analysis)
Sections 236 and 206.2.13 of the 2004 ADAAG require one of each type of fixed exercise machine to meet clear floor space specifications and to be on an accessible route....
-
4.13.6 MANEUVERING CLEARANCES AT DOORS
The floor or ground area within the required clearances shall be level and clear....
-
4.34.5.5(2) Seat
The seat shall be 17 in to 19 in (430 mm to 485 mm) high measured from the bathroom floor and shall extend the full depth of the stall....
-
Horizontal Exits [IBC §1021 (2003), §1005.3.5 (2000)]
allowing occupants to exit the area containing the origin of a fire into another portion of the building that is protected by fire-resistance-rated assemblies (doors, walls, ceilings, and floors...
-
11B-605.4 Flush controls
Hand operated flush controls shall comply with Section 11B-309 except that the flush control shall be mounted at a maximum height of 44 inches (1118 mm) above the finish floor....