Exception: The enforcing agency may reduce the size of each required area of refuge to accommodate one wheelchair space that is not less than 30 inches by 52 inches (762 mm by 1320 mm) on floors...
Search Results "Floor Surface"
-
1009.6.3 Size
-
406.2.2 Clear height
The clear height of each floor level in vehicle and pedestrian traffic areas shall be not less than 7 feet (2134 mm)....
-
Designations: ADA Standard Section 216.2
Section 216.2 covers scoping requirements in the current ADA Standards for sign designations.
-
1009.6.3 Size
Exception: The enforcing agency may reduce the size of each required area of refuge to accommodate one wheelchair space that is not less than 30 inches by 52 inches (762 mm by 1320 mm) on floors...
-
Protrusion Limits: ADA Standard Section 307.2
Section 307.2 covers the current ADA Standards for protrusion limits.
-
SECTION 1017 AISLES
for applications listed in Section 1.9.1 regulated by the Division of the State Architect-Access Compliance, shall also comply with Chapter 11A or Chapter 11B, Section 11B-403 _|Walking Surfaces...
-
Transition Plates
Transition Plates Transition plates are sloping pedestrian walking surfaces located at the end of a gangway....
-
Width and Length
This provides enough space for a person to sit comfortably on the surface of the wall and pivot to access the water....
-
Maneuvering Space Where Ramps are Provided
The ADA and ABA Accessibility Guidelines address additional requirements for ramps and landings including edge protection, cross slope, surfaces, and outdoor conditions....
-
505.10.1 Top and Bottom Extension at Ramps
Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent ramp run....
-
Transition Plates
Transition Plates Transition plates are sloping pedestrian walking surfaces located at the end of a gangway....
-
R305.2 Placement
The placement of detectable warning surfaces shall comply with R305.2. Advisory R305.2 Placement. Some detectable warning products require a concrete border for proper installation....
-
1018.10 Dune Crossings
The curbs or barriers are required to prevent the passage of a 2 inch diameter sphere, where any portion of the sphere is within 2 inches of the crossing surface....
-
11B-1009.5.2 Transfer space
A transfer space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
§ 38.119(b)
doorways of cars not operating at lighted station platforms shall have outside lights which, when the door is open, provide at least 1 foot-candle of illumination on the station platform surface...
-
§ 38.81(c)
(c) The doorways of vehicles not operating at lighted station platforms shall have outside lights which provide at least 1 foot-candle of illumination on the station platform or street surface...
-
11B-407.4.6.2.1 Size and shape
Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding surface...
-
11B-1009.5.2 Transfer space
A transfer space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
1009.5.2 Transfer Space
A transfer space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
505.10.1 Top and Bottom Extension at Ramps
Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent ramp run....
-
505.10.3 Bottom Extension at Stairs
Extension shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight....
-
505.10.2 Top Extension at Stairs
Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight....
-
603.4 Coat Hooks and Shelves
Shelves shall be located 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor. [ECTCR UFAS 4.25.3, Fig. 38]...
-
308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or...