will accommodate most irregularities or variances due to construction methods or materials according to a study sponsored by the Board (“Dimensional Tolerances in Construction and for Surface...
Search Results "End Transfer Surface"
-
Slope [§405.2] and Cross Slope [§405.3]
-
Some existing measurement protocols
Some existing measurement protocols Currently there are no generally accepted measurement protocols for determining the slope, flatness, or waviness of floor surfaces in terms of accessibility...
-
Changes in Level at Entry to Wheelchair Spaces (M303.3)
with drop offs ½ inch or greater would be required to provide edge protection 2 inches high minimum on each side to prevent users from inadvertently travelling off the sides of the ramped surface...
-
11B-704.4.1 Height
When in use, the touch surface of TTY keypads shall be 34 inches (864 mm) minimum above the finish floor....
-
11B-308.3.2 Obstructed high reach
Operable parts of fuel dispensers shall be permitted to be 54 inches (1372 mm) maximum measured from the surface of the vehicular way where fuel dispensers are installed on existing curbs...
-
1133A.2 Clear floor space
A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows either a parallel or a forward approach shall be provided at the work surface required by Section 1133A...
-
11B-704.4.1 Height
When in use, the touch surface of TTY keypads shall be 34 inches (864 mm) minimum above the finish floor....
-
11B-308.3.2 Obstructed high reach
Operable parts of fuel dispensers shall be permitted to be 54 inches (1372 mm) maximum measured from the surface of the vehicular way where fuel dispensers are installed on existing curbs...
-
11B-703.7.2.6 Toilet and bathing facilities geometric symbols
Geometric symbols at entrances to toilet and bathing rooms shall be mounted at 58 inches (1473 mm) minimum and 60 inches (1524 mm) maximum above the finish floor or ground surface measured...
-
604.7 Dispensers
paper dispensers are installed above the side wall grab bar, the outlet of the toilet paper dispenser must be 48 inches (1220 mm) maximum above the finish floor and the top of the gripping surface...
-
308.3.2 Obstructed High Reach
Operable parts of fuel dispensers shall be permitted to be 54 inches (1370 mm) maximum measured from the surface of the vehicular way where fuel dispensers are installed on existing curbs...
-
5.8.2.1 Height of Breast Platform at Time of Measurement
However, the top surface of the breast platform is a well-defined surface, and defines where the patient’s chest will be during the exam....
-
Alterations to Existing Facilities
For example, if an alteration project involves only installing pedestrian signals at existing intersections and there are no detectable warning surfaces on the curb ramps at the intersections...
-
Slopes and Resting Intervals for Beach Access Routes
When the surface is paved or is built with boards, the cross slope is not allowed to be steeper than 1:48 (2 percent)....
- Bradley Towel Dispenser 250-33
-
11B-404.2.9 Door and gate opening force
and the centerline of the second push plate shall be 30 inches (762 mm) minimum and 44 inches (1118 mm) maximum above the floor or ground surface....
-
11B-404.2.9 Door and gate opening force
and the centerline of the second push plate shall be 30 inches (762 mm) minimum and 44 inches (1118 mm) maximum above the floor or ground surface....
-
11B-404.2.9 Door and gate opening force
and the centerline of the second push plate shall be 30 inches (762 mm) minimum and 44 inches (1118 mm) maximum above the floor or ground surface....
- EZ-ACCESS Transitions® Modular Entry Ramp
-
James E. Woods, Ph.D., P.E. Natural Lighting for Persons with Low Vision
Somebody questioned a minute ago: What is the ratio of daylight on the surface, horizontal surface, to the lighting level that you want inside? That’s a daylight factor....
- SDC Push Plate Switch
- AJW Architectural Products UG3-A Series UG3-A12 12" Concealed Snap Flange, 1.5" Diameter Grab Bar - Configuration A
- AJW Architectural Products UG130-A Series UG130-A12 12" Exposed Flange, 1.5" Diameter Grab Bar - Configuration A
- AquaTrek2 ADA Step System