2. c. REACH RANGES
Figure 18 (high forward reach range), and Figure 19 (side reach range) illustrate reach ranges accessible to wheelchair users or people with limited mobility....
-
United States of America v. Camp Bravo - Settlement Agreement
SETTLEMENT AGREEMENT BETWEEN THE UNITED STATES OF AMERICA AND CAMP BRAVO UNDER THE AMERICANS WITH DISABILITIES ACT DJ # 202-35-304...
-
Key Study findings:
The majority of participants (e.g. the 5th percentile or approximately 95% of the study sample) could transfer independently to a platform at a height that was within one inch...
-
Study Objectives
The purpose of this study was to examine independent transfers to and from a WMD and a simple platform, with and without the use of grab bars and/or a backrest, and transfers between...
-
CHAPTER 5: DOORWAYS, CIRCULATION PATHS AND FARE COLLECTION DEVICES
[See subsections ...]
-
§ 382.57(c)(3)(i) Identification
(i) Identification. Operable parts must be tactilely discernible without activation;
-
§ 36.302(f)(4)
(4) Purchasing multiple tickets.
-
2. d. PATIENT RECEPTION DESKS
Reception desks should have a lower section where scooter and wheelchair users and people of short stature can easily communicate with staff. Compliant height range is 28 - 34...
-
4.2.6 Clear Floor or Ground Space
At least 48 inches (1220 mm) by 48 inches (1220 mm) of clear floor or ground space shall be provided on all usable sides of fire rings, grills, fireplaces or woodstoves. This space...
-
4.5.2 Clear Floor or Ground Space
A clear floor or ground space shall be provided for each trash, recycling, and other essential container. The space shall be positioned for either forward or side approach to the...
-
8.3 Alternate Means of Access
of MDE is more accessible than equipment is now....
-
§27.71(k)
(k) Shared-use automated airport kiosks provided in accordance with paragraph (j) of this section must conform to the following technical accessibility standards with respect to their physical...
-
§ 27.71(k)
(k) Shared-use automated airport kiosks provided in accordance with paragraph (j) of this section must conform to the following technical accessibility standards with respect to their physical...
-
PRIVATE BUILDING OR FACILITY
[DSA-AC] A place of public accommodation or a commercial building or facility subject to Chapter 1, Section 1.9.1.2. [2010 ADA Standards 106.5] Private Building or Facility....
-
PUBLIC USE
[DSA-AC] Interior or exterior rooms, spaces or elements that are made available to the public. Public use may be provided at a building or facility that is privately or publicly owned....
-
Website Accessibility Evaluation
Accessibility Evaluation....
- Sony Entertainment Access Glasses
-
For EV with the charging port at rear of the vehicle, can EV be assumed to be able to back in the parking space for easy access to the charger at the head location?
RESPONSE: This practice is not regulated by the CBC Chapter 11B accessibility provisions. DSA is not aware of any restrictions on this practice....
-
5. Ground Level PV Systems
For purposes of accessibility compliance, ground level PV systems fall into one of the two following types: 5A – Restricted Access: The PV system components are located within a secure...