The deck surface between the centerline of the seat and the pool edge shall have a slope not steeper than 1:48. FIGURE 11B-1009.2.2 POOL LIFT SEAT LOCATION...
Search Results "Floor Surface"
-
11B-1009.2.2 Seat location
-
R409.10.3 Bottom Extension at Stairways
Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight....
-
R409.10.2 Top Extension at Stairways
Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight....
-
11B-503.3.3 Marking
The area within the borderlines shall be marked with hatched lines a maximum of 36 inches (914 mm) on center in a color contrasting with that of the aisle surface....
-
APPENDIX A. GUIDELINES FOR SERVICE ANIMAL RELIEF AREAS (SARA)
A.4 Surfaces. A relief area should have at least two different surfaces. One should be hard and located immediately inside the entrance to allow wheelchair access....
-
Elevators
The "Disco" elevator hoist way entrance lacks raised and Braille floor designations on both jambs and the elevator emergency call system does not operate without voice communication....
-
2e
Is there a horizontal grab bar along each of the three shower walls at 33"-36" above the floor as shown in Figure 37(b) below?...
-
H16
Is the toilet stall at least 60 inches wide and 56 inches deep (wall mounted toilet) or 59 inches deep (floor mounted toilet)?...
-
H8
If lavatories are provided, does at least one have at least a 29 inch high clearance under the front apron with the top of the rim no more than 34 inches above the floor?...
-
11B-411.2.1.7.4 Adjacency assignment
Exception: The most adjacent elevator serving the selected floor shall be assigned by hall call consoles located outside the elevator landing....
-
306.2.4 Additional Clearance
Space extending greater than 6 inches (150 mm) beyond the available knee clearance at 9 inches (230 mm) above the finish floor or ground shall not be considered toe clearance....
-
Water Closets [4.16]
Clear floor space requirements at a toilet not located in a stall are different from those for a toilet within a stall....
-
11B-602.7 Drinking fountains for standing persons
Spout outlets of drinking fountains for standing persons shall be 38 inches (965 mm) minimum and 43 inches (1092 mm) maximum above the finish floor or ground....
-
11B-411.2.1.7.4 Adjacency assignment
Exception: The most adjacent elevator serving the selected floor shall be assigned by hall call consoles located outside the elevator landing....
-
§ 38.81(b)
doorways with lifts, ramps or bridge plates, shall have, at all times, at least 2 foot-candles of illumination measured on the step tread or lift or ramp, when deployed at the vehicle floor...
-
11B-411.2.1.7.4 Adjacency assignment
Exception: The most adjacent elevator serving the selected floor shall be assigned by hall call consoles located outside the elevator landing....
-
705.1.2 Dome Spacing
Truncated domes in a detectable warning surface shall have a center-to-center spacing of 1.6 inches (41 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
-
Seat Height
Seat Height The lift must be designed so that the seat will make a stop between a minimum of 16 inches and maximum of 19 inches (measured from the deck to the top of the seat surface,...
-
11B-505.10.1 Top and bottom extension at ramps
Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent ramp run....
-
4.7.2 SLOPE
Maximum slopes of adjoining gutters, road surface immediately adjacent to the curb ramp, or accessible route shall not exceed 1.20....
-
1131A.2 Changes greater than ½ inch
Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units horizontal (5-percent slope), or a ramp, elevator or...
-
13) Detectable warnings
Must be a textured surface on the door handle or hardware (§4.29)....
-
1131A.2 Changes greater than ½ inch
Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units horizontal (5-percent slope), or a ramp, elevator or...
-
11B-503.3.3 Marking
The area within the borderlines shall be marked with hatched lines a maximum of 36 inches (914 mm) on center in a color contrasting with that of the aisle surface....