In the final rule, the specified clearance between grab bars and dispensers mounted above them has been revised for consistency with the grab bar specifications in section 609....
Search Results "Vertical Clearance"
-
Toilet Paper Dispensers
-
Play Tables
Where play tables are located on an accessible route, the wheelchair knee clearance minimums are: 24 inches (610 mm) high minimum 30 inches (760 mm) wide minimum...
-
1003.3 Clearances
Clearances at boat slips and on boarding piers at boat launch ramps shall comply with 1003.3. Advisory 1003.3 Clearances....
-
1003.3 Clearances
Clearances at boat slips and on boarding piers at boat launch ramps shall comply with 1003.3. Advisory 1003.3 Clearances....
-
11B-306.3.1 General
Space under an element between 9 inches (229 mm) and 27 inches (686 mm) above the finish floor or ground shall be considered knee clearance and shall comply with Section 11B-306.3....
-
11B-306.3.1 General
Space under an element between 9 inches (229 mm) and 27 inches (686 mm) above the finish floor or ground shall be considered knee clearance and shall comply with Section 11B-306.3. ...
-
11B-306.3.1 General
Space under an element between 9 inches (229 mm) and 27 inches (686 mm) above the finish floor or ground shall be considered knee clearance and shall comply with Section 11B-306.3....
- TownSteel ED1300 Grade 1 Concealed Vertical Rod Panic Device
-
404.2.4.1 Swinging Doors and Gates
Swinging doors and gates shall have maneuvering clearances complying with Table 404.2.4.1....
-
404.2.4.1 Swinging Doors and Gates
Swinging doors and gates shall have maneuvering clearances complying with Table 404.2.4.1....
-
11B-206.2.3.2 Distance to Elevators
In new construction of buildings where elevators are required by Section 11B-206.2.3, and which exceed 10,000 square feet (929 m2) on any floor, an accessible means of vertical access via...
-
11B-206.2.3.2 Distance to Elevators
In new construction of buildings where elevators are required by Section 11B-206.2.3, and which exceed 10,000 square feet (929 m2) on any floor, an accessible means of vertical access via...
-
11B-206.2.3.2 Distance to Elevators
In new construction of buildings where elevators are required by Section 11B-206.2.3, and which exceed 10,000 square feet (929 m2) on any floor, an accessible means of vertical access via...
-
1017.4.1 Size
Vertical alignment at the intersection of the trails that form the T-shaped space shall be nominally planar. Advisory 1017.4.1 Size. ...
-
1017.4.1 Size
Vertical alignment at the intersection of the trails that form the T-shaped space shall be nominally planar. Advisory 1017.4.1 Size....
-
Location and Dispersion
[See subsections ...]
-
407.12.2 Side Reach (Section-by-Section Analysis)
407.12.2 Side Reach (Section-by-Section Analysis) This section specifies proposed requirements for operable parts providing unobstructed or obstructed side reaches. It proposes to...
-
M9
Does the lavatory have at least a 29-inch-high clearance under the front edge and the top of the rim no more than 34 inches above the floor?...
-
304.3.2 T-Shaped Space
The space shall be permitted to include knee and toe clearance complying with 306 only at the end of either the base or one arm....
-
304.3.2 T-Shaped Space
The space shall be permitted to include knee and toe clearance complying with 306 only at the end of either the base or one arm....
-
404.2.4.3 Recessed Doors and Gates
Maneuvering clearances for forward approach shall be provided when any obstruction within 18 inches (455 mm) of the latch side of a doorway projects more than 8 inches (205 mm) beyond the...
-
11B-304.3.2 T-Shaped space
The space shall be permitted to include knee and toe clearance complying with Section 11B-306 only at the end of either the base or one arm. ...
-
11B-304.3.2 T-Shaped space
The space shall be permitted to include knee and toe clearance complying with Section 11B-306 only at the end of either the base or one arm....