4.29.5* TACTILE WARNINGS AT HAZARDOUS VEHICULAR AREAS
-
A4.29.5 TACTILE WARNINGS AT HAZARDOUS VEHICULAR AREAS
(Reserved).
-
11B-705.1.2.2 Curb ramps
Detectable warnings at curb ramps shall extend 36 inches (914 mm) in the direction of travel....
-
Platform Edges
Platform Edges The detectable warning must be placed at the platform edge and extend the full platform length in a 24 inch depth. This depth is an absolute dimension, not a minimum....
-
11B-705.1.2.2 Curb ramps
Detectable warnings at curb ramps shall extend 36 inches (914 mm) in the direction of travel....
-
11B-247.1.2.6 Reflecting pools
The edges of reflecting pools shall be protected by railings, walls, warning curbs or detectable warnings complying with Sections 11B-705.1.1 and 11B-705.1.2.6. ...
-
11B-247.1.2.6 Reflecting pools
The edges of reflecting pools shall be protected by railings, walls, warning curbs or detectable warnings complying with Sections 11B-705.1.1 and 11B-705.1.2.6....
-
11B-247.1.2.6 Reflecting pools
The edges of reflecting pools shall be protected by railings, walls, warning curbs or detectable warnings complying with Sections 11B-705.1.1 and 11B-705.1.2.6....
-
A4.33.7 TYPES OF LISTENING SYSTEMS
A listening system that can be used from any seat in a seating area is the most flexible way to meet this specification....
-
Sennheiser HDI 1029 Multi-Channel Infrared Stethoset Receiver
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Sennheiser SI 1015 Wideband Modulator
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Sennheiser SI 29-5 Five-Channel Modulator
Requires the Premium User plan or above. (Login or upgrade your account!)
-
A4.33.7 Types of Listening Systems
Radio frequency systems can be extremely effective and inexpensive....
-
11B-247.1.2.4 Bus stops
Where detectable warnings are provided at bus stop boarding and alighting areas in compliance with Section 11B-810.2.3, detectable warnings shall comply with Sections 11B-705.1.1 and 11B...
-
11B-247.1.2.4 Bus stops
Where detectable warnings are provided at bus stop boarding and alighting areas in compliance with Section 11B-810.2.3, detectable warnings shall comply with Sections 11B-705.1.1 and 11B...
-
15) Curb ramps
15) Curb ramps ADAAG: Curb ramps must have detectable warnings (which must be raised truncated domes) (§4.7.7). UFAS: No requirement for detectable warnings on curb ramps....
-
11B-247.1.2.4 Bus stops
Where detectable warnings are provided at bus stop boarding and alighting areas in compliance with Section 11B-810.2.3, detectable warnings shall comply with Sections 11B-705.1.1 and 11B...
-
Section 406.8
Section 406.8 To maintain the status quo with respect to detectable warnings in pedestrian facilities, the Department is adding a provision (not found in the current version of the new...
-
R305.2.5 Pedestrian At-Grade Rail Crossings
At pedestrian at-grade rail crossings not located within a street or highway, detectable warning surfaces shall be placed on each side of the rail crossing....
-
Emergency Communication [§407.4.9]
Emergency Communication [§407.4.9] The ASME A17.1 code requires a two-way means of emergency communication in elevator cars....
-
11B-705.1.2.4 Bus stops
When detectable warnings are provided at bus stop boarding and alighting areas, the detectable warnings shall extend the full width of the boarding/alighting area and shall be 36 inches...
-
11B-705.1.2.4 Bus stops
When detectable warnings are provided at bus stop boarding and alighting areas, the detectable warnings shall extend the full width of the boarding/alighting area and shall be 36 inches...
-
11B-705.1.2.4 Bus stops
When detectable warnings are provided at bus stop boarding and alighting areas, the detectable warnings shall extend the full width of the boarding/alighting area and shall be 36 inches...
-
907.2.6.2.1 System initiation
Actuation of an automatic fire-extinguishing system, a manual fire alarm box or a fire detector shall initiate an approved fire alarm signal which automatically notifies staff....