607.4 Grab Bars (Exception 2) Exception 2 to this section permits grab bars to not be installed at bathtubs in residential dwelling units required to provide mobility features provided...
Search Results "Dwelling Unit (FHA)"
Commonly Searched Documents
-
607.4 Grab Bars (Exception 2)
-
809.5.1.1 Alarm Appliances
Where alarm appliances are provided within a residential dwelling unit as part of the building fire alarm system, they shall comply with 702....
-
809.5.1.1 Alarm Appliances
Where alarm appliances are provided within a residential dwelling unit as part of the building fire alarm system, they shall comply with 702....
-
Introduction
and certain types of units within covered multifamily dwellings....
-
11B-233.2 Reserved
[2010 ADA Standards] 233.2 Residential Dwelling Units Provided by Entities Subject to HUD Section 504 Regulations....
-
11B-224.7.2 Multi-bedroom housing units with adaptable features
Accessible dwelling units with adaptable features shall be provided as required by Section 11B-233.3.1.2....
-
11B-809.1 General
When located within public housing facilities, residential dwelling units shall comply with Section 11B-809....
-
11B-809.1 General
When located within public housing facilities, residential dwelling units shall comply with Section 11B-809....
-
11B-809.1 General
When located within public housing facilities, residential dwelling units shall comply with Section 11B-809....
-
809.5.1.1 Alarm Appliances
Where alarm appliances are provided within a residential dwelling unit as part of the building fire alarm system, they shall comply with 702....
-
VI. Relationship to Other Laws
with certain features of accessible design.22 The FHAct design and construction requirements apply to ‘‘covered multifamily dwellings’’ designed and constructed for first occupancy after...
-
804.3 Kitchen Work Surface
In residential dwelling units required to comply with 809, at least one 30 inches (760 mm) wide minimum section of counter shall provide a kitchen work surface that complies with 804.3....
-
804.3 Kitchen Work Surface
In residential dwelling units required to comply with 809, at least one 30 inches (760 mm) wide minimum section of counter shall provide a kitchen work surface that complies with 804.3....
-
11B-233.3.4 Alterations
Clarifies in the exception the technical requirements for accessible residential dwelling units when alterations are made to existing public housing facilities are technically infeasible...
-
1150A.1 General
Except as provided for in Section 1102A.3.1, the provisions of this section do not apply to multistory dwelling units in non-elevator buildings....
-
1133A.2.1 Clear width
Kitchens shall have a minimum clear width measured between any cabinet, countertop or the face of any appliance (excluding handles and controls) that projects into the kitchen and...
-
1133A.2.1, Item 3
3. All other kitchen designs shall provide a minimum clear width of at least 48 inches (1219 mm). (See Figure 11A-10A).
-
1132A.4.1, Item 1
1. Thresholds with a change in height of not more than ¼ inch (6.35 mm) may be vertical.
-
1136A.1 Receptacle heights
1136A.1 Receptacle heights. Electrical receptacle outlets on branch circuits of 30 amperes or less and communication system receptacles shall be located no more than 48 inches (1219...
-
1132A.8 Hand-activated door hardware
1132A.8 Hand-activated door hardware. Hand-activated door latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor....
-
1132A.7 Type of lock or latch
1132A.7 Type of lock or latch. The type of latch and lock required for all doors shall be in accordance with Section 1132A.8 and Chapter 10, Section 1008.
-
1133A.5 Lower shelving
1133A.5 Lower shelving. Lower shelving and/or drawer space shall be provided in the kitchen at a height of no more than 48 inches (1219 mm) above the floor.
-
4.34.2(14)
(14) If laundry facilities are provided, they shall comply with 4.34.7.
-
A4.34.6.7 OVENS
Countertop or wall-mounted ovens with side-opening doors are easier for people in wheelchairs to use. Clear spaces at least 30 in (760 mm) wide under counters at the side of ovens...