4.3 Q. If the only new construction is an addition consisting of four or more dwelling units, would the existing public and common use spaces have to be made accessible?
The Fair Housing Act applies to new construction of covered multifamily dwellings. (See section 804(f)(3)(C)(i) of the Act.)...
-
11B-809.7.1 Width
The clear width for the accessible route shall be 36 inches (914 mm) minimum. Exception: The clear width shall be permitted to be reduced to 32 inches (813 mm) minimum at doors.
-
11B-809.10.6 Showers
Showers required by Section 11B-809.10 shall comply with this section.
-
11B-809.2.2 Turning space
All rooms served by an accessible route shall provide a turning space complying with Section 11B-304. Exception: Turning space shall not be required in exterior spaces 30 inches...
-
11B-809.2.2 Turning space
All rooms served by an accessible route shall provide a turning space complying with Section 11B-304. Exception: Turning space shall not be required in exterior spaces 30 inches...
-
11B-809.12 Electrical receptacles, controls and switches
Electrical receptacles on branch circuits of 30 amperes or less, communication system receptacles, controls and switches shall be located as follows: Where there is no...
-
Turning Space: ADA Standard Section 809.2.2
All rooms served by an accessible route shall provide a turning space complying with 304. EXCEPTION: Turning space shall not be required in exterior spaces 30 inches (760 mm)...
-
11B-809.10.6 Showers
Showers required by Section 11B-809.10 shall comply with this section.
-
11B-809.9.6 Controls
Controls for faucets shall comply with Section 11B-309.1. Hand-operated metering faucets shall remain open for 10 seconds minimum.
-
11B-809.7.2 Changes in level
Changes in level shall comply with Sections 11B-303.2 and 11B-303.3. Ramps complying with Section 11B-405, elevators complying with Section 11B-407 or platform lifts complying with...
-
11B-809.12 Electrical receptacles, controls and switches
Electrical receptacles on branch circuits of 30 amperes or less, communication system receptacles, controls and switches shall be located as follows: Where there is no...
-
11B-809.7.1 Width
The clear width for the accessible route shall be 36 inches (914 mm) minimum. Exception: The clear width shall be permitted to be reduced to 32 inches (813 mm) minimum at doors.
-
11B-809.7.2 Changes in level
Changes in level shall comply with Sections 11B-303.2 and 11B-303.3. Ramps complying with Section 11B-405, elevators complying with Section 11B-407 or platform lifts complying with...
-
11B-809.9.6 Controls
Controls for faucets shall comply with Section 11B-309.1. Hand-operated metering faucets shall remain open for 10 seconds minimum.
-
809.1 General
Residential dwelling units required to provide mobility features shall comply with 809.2 through 809.4....
-
809.5.4 Prohibited Use
Visible alarm appliances used to indicate residential dwelling unit smoke detection or building fire alarm activation shall not be used for any other purpose within the residential dwelling...
-
809.5.4 Prohibited Use
Visible alarm appliances used to indicate residential dwelling unit smoke detection or building fire alarm activation shall not be used for any other purpose within the residential dwelling...
-
11B-208.2.3.1 Parking for residents
Where at least one parking space is provided for each residential dwelling unit, at least one parking space complying with Section 11B-502 shall be provided for each residential dwelling...
-
11B-208.2.3.1 Parking for residents
Where at least one parking space is provided for each residential dwelling unit, at least one parking space complying with Section 11B-502 shall be provided for each residential dwelling...
-
14.3 Q...are there any requirements for the inside dimensions of these individual parking garages?
These garages would be public and common use space, even though the individual garages may be assigned to a particular dwelling unit....
-
14.1 Q. How many resident parking spaces must be made accessible at the time of construction?
The Guidelines provide that a minimum of two percent of the parking spaces serving covered dwelling units be made accessible and located on an accessible route to wheelchair users....
-
809.5.4 Prohibited Use
Visible alarm appliances used to indicate residential dwelling unit smoke detection or building fire alarm activation shall not be used for any other purpose within the residential dwelling...
-
General: ADA Standard Section 229.1
Section 229.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for windows.