An accessible examination room has features that make it possible for patients with mobility disabilities, including those who use wheelchairs, to receive appropriate medical care....
Search Results "Adjustable Height Counter"
-
PART 3: ACCESSIBLE EXAMINATION ROOMS
-
M301.4.1 Clearance in Base (Section-by-Section Analysis)
Secondly, the Access Board has decided to retain the six-inch height clearance requirement but agrees with the commenters that the diagnostic equipment should not have to meet the six-inch...
-
11B-220.2 Point-of-sale devices
Where point-of-sale devices are provided at check stands and sales and service counters required to comply with Sections 11B-227.2 and 11B-227.3, they shall comply with Sections 11B-707.2...
-
5.1.5 Floor Height
Where the floor at the entrance to the camp shelter is elevated above the ground surface, the floor shall be 17 (430 mm) high minimum to 19 inches (485 mm) high maximum measured from...
-
602.4 Spout Height
602.4 Spout Height. Spout outlets shall be 36 inches (915 mm) maximum above the finish floor or ground....
-
The Brewer Company, LLC
for adjustable height transfer surfaces....
-
11B-220.2 Point-of-sale devices
Where point-of-sale devices are provided at check stands and sales and service counters, they shall comply with Section 11B-707.9.1, and shall also comply with Sections 11B-707.2 _|Clear...
- 605.2 Urinal Height to Rim
-
4.7.9.3 Height
The counter or rim of the sink shall be no more than 34 inches (865 mm) above the floor or ground....
- Brewer Assist Power Procedure Table™
-
A2.2 Equivalent Facilitation
equivalent facilitation are found in the following sections: 4.1.6(3)(c) Elevators in Alterations 4.31.9 Text Telephones 7.2 Sales and Service Counters...
-
505.4 Height
505.4 Height....
-
8.3 CHECK-OUT AREAS
At least one lane at each check-out area shall comply with 4.32. Any traffic control or book security gates or turnstiles shall comply with 4.13.
-
11B-220.2 Point-of-sale devices
Where point-of-sale devices are provided at check stands and sales and service counters required to comply with Sections 11B-227.2 and 11B-227.3, they shall comply with Sections 11B-707.2...
-
505.4 Height
Handrails shall be at a consistent height above walking surfaces, stair nosings, and ramp surfaces. Advisory 505.4 Height....
-
4.30.3 Character Height
The minimum height is measured using an upper case X. Lower case characters are permitted....
-
505.4 Height
Handrails shall be at a consistent height above walking surfaces, stair nosings, and ramp surfaces. [ECTCR UFAS 4.8.5(5), 4.9.4(5)] Advisory 505.4 Height....
-
PART 4: ACCESSIBLE MEDICAL EQUIPMENT
Such equipment includes adjustable-height exam tables and chairs, wheelchair-accessible scales, adjustable-height radiologic equipment, portable floor and overhead track lifts, and gurneys...
-
703.5.6 Height From Finish Floor or Ground
Visual characters shall be 40 inches (1015 mm) minimum above the finish floor or ground. EXCEPTION: Visual characters indicating elevator car controls shall not be required to...
-
7. Lavatory
7. Is the lavatory (wash basin) in each accessible guestroom bathroom no more than 34" high with at least 29" high clearance under the front edge to allow persons who use wheelchairs...
- Exam Tables & Scales: What Patients Say...
-
11B-1009.2.4 Seat
The height of the lift seat shall be designed to allow a stop at 17 inches (432 mm) minimum to 19 inches (483 mm) maximum measured from the deck to the top of the seat surface when in the...
-
1009.6.1 Pool Stairs