The powered leaf(s) shall be located closest to the accessible route. a. Powered doors shall comply with Section 11B-404.3....
Search Results "Shall"
-
11B-404.2.9 Door and gate opening force
-
Islands: ADA Standard Section 406.7
Section 406.7 covers the current ADA Standards for islands.
-
11B-703.4.2 Location
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side....
-
11B-703.4.2 Location
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side....
-
Extended Ground or Deck Surface: ADA Standard Section 1005.3.2
The ground or deck surface shall extend 12 inches (305 mm) minimum beyond the inside face of the railing....
-
Maneuvering Clearance: ADA Standard Section 404.3.2
Section 404.3.2 covers the current ADA Standards for maneuvering clearance at automatic and power-assisted doors and gates.
-
11B-411.2.1.3.4 Position
Display screens and touch screens shall be positioned so glare is reduced on the screen. Keypads or buttons shall slope away from the user at 15 to 25 degrees from the vertical plane....
-
11B-810.8 Clocks
Where clocks are provided for use by the public, the clock face shall be uncluttered so that its elements are clearly visible....
-
11B-1005.3.2 Extended ground or deck surface
The ground or deck surface shall extend 12 inches (305 mm) minimum beyond the inside face of the railing....
-
11B-411.2.1.5.1 Size
Buttons shall have square shoulders, be 3/4 inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding...
-
11B-308.1.1 Electrical switches
Controls and switches intended to be used by the occupant of a room or area to control lighting and receptacle outlets, appliances or cooling, heating and ventilating equipment, shall comply...
-
11B-813.2.1.3 Height and operation
Adult changing table height shall be adjustable from 17 inches (432 mm) above the floor or ground to 38 inches (965 mm) above the floor or ground, as measured to the top of the changing...
-
11B-810.8 Clocks
Where clocks are provided for use by the public, the clock face shall be uncluttered so that its elements are clearly visible....
-
11B-411.2.1.3.4 Position
Display screens and touch screens shall be positioned so glare is reduced on the screen. Keypads or buttons shall slope away from the user at 15 to 25 degrees from the vertical plane....
-
11B-1005.3.2 Extended ground or deck surface
The ground or deck surface shall extend 12 inches (305 mm) minimum beyond the inside face of the railing....
-
11B-411.2.1.5.1 Size
Buttons shall have square shoulders, be 3/4 inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding...
-
11B-813.2.1.3 Height and operation
Adult changing table height shall be adjustable from 17 inches (432 mm) above the floor or ground to 38 inches (965 mm) above the floor or ground, as measured to the top of the changing...
-
11B-308.1.1 Electrical switches
Controls and switches intended to be used by the occupant of a room or area to control lighting and receptacle outlets, appliances or cooling, heating and ventilating equipment, shall comply...
-
11B-502.3.4 Location
Access aisles shall not overlap the vehicular way....
-
11B-502.3.4 Location
Access aisles shall not overlap the vehicular way....
-
11B-809.8.3 Door maneuvering clearance.
Minimum maneuvering clearances at doors shall comply with Section 11B-809.8.3. ...
-
Keypads: ADA Standard Section 407.4.6.3
Section 407.4.6.3 covers the current ADA Standards for elevator car control keypads.
-
Braille Instructions: ADA Standard Section 707.8
Braille instructions for initiating the speech mode shall be provided. Braille shall comply with 703.3....
-
Toilet Rooms and Bathing Rooms: ADA Standard Section 216.8
Section 216.8 covers scoping requirements in the current ADA Standards for signs at toilet rooms and bathing rooms.