Each transfer surface shall provide two unobstructed sides for patient transfer. EXCEPTIONS: 1. Obstructions no more than 3 inches (75 mm) deep shall be permitted to extend beyond...
Search Results "Picnic Table"
Commonly Searched Documents
-
M301.2.4 Unobstructed Transfer
-
M301.4 Lift Compatibility
Diagnostic equipment shall be usable with portable patient lifts and, when in use with such lifts, shall comply with M301.4.1 or M301.4.2. EXCEPTION: Where fixed overhead patient...
-
M301.2.4 Unobstructed Transfer (Section-by-Section Analysis)
In the MDE NPRM the Access Board proposed that each transfer side provide unobstructed access to the transfer surface, with an exception to permit temporary obstructions as long as...
-
M301.4 Lift Compatibility
Diagnostic equipment shall be usable with a patient lift and shall comply with M301.4.1 or M301.4.2.
-
M301.2.3 Transfer Sides
The transfer surface shall be located to provide options to transfer from a mobility device onto one short side (depth) and one long side (width) of the surface. Each transfer side...
-
(3) Adjustability: Transfer Surface Intermediate Heights
Adjustable height MDE, such as exam tables, imaging tables and chairs, will make it possible to position the transfer surface near the height of the seat of the mobility device....
-
M305.2.1 Location (Section-by-Section Analysis)
The Committee noted that: because of the size, diversity, and use of diagnostic imaging tables, this support will carry out different functions on different tables… This two-part...
- Kompan, Inc. ELE400101 - Ministudio Sand Play Structure
-
11B-226.4 Baby diaper changing station
Baby diaper changing stations shall comply with Sections 11B-309 and 11B-902. Baby diaper changing stations when deployed shall not obstruct the required width of an accessible route...
-
5.1.3 Transfer Surface Low Height Options for M301 and M302
The Imaging Subcommittee recommended deferring this issue to the Table and Chairs Subcommittee....
-
M301 Diagnostic Equipment Used by Patients in Supine, Prone, or Side-Lying Position
[See subsections ...]
-
How Can You Overcome These Barriers to Work with Your Providers?
There are many things that a person with a disability can do to improve his or her quality of health care and break down the barriers that compromise care. The following suggestions...
-
M301 Diagnostic Equipment Used by Patients in Supine, Prone, or Side-Lying Position
[See subsections ...]
-
17 Inch Low Height
She stated that a 14 inch high transfer surface on tables and chairs would be ideal to facilitate the safest transfers, noting that 17 inches can be too high for some people. Ms....
-
5.4.4 Transfer Support Distance from Transfer Surface Recommendations for M301 and M302
The above technical criteria would likely result in the transfer surface being located at the foot end of examination tables and allow the use of transfer supports similar to the side rails...
-
M305.2.2 Length
The length of transfer supports shall comply with M305.2.2.1 or M305.2.2.2.
-
M301.2.1 Height
The height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured from the floor to the top of the transfer...
-
5.1.4 Transfer Surface Height Measurement for M301 and M302
This recommendation applies to exam tables and chairs and this measurement may not necessarily be at the centerline of the seat where there are higher points on the seat....
-
36 CFR Part 1195 Proposed Accessibility Standards for Medical Diagnostic Equipment NPRM - Preamble
The proposed standards contain minimum technical criteria to ensure that medical diagnostic equipment, including examination tables, examination chairs, weight scales, mammography equipment...
-
F202.4 Alterations Affecting Primary Function Areas
Camping facilities, picnic facilities, viewing areas, trailheads, trails, and beach access routes shall not be required to comply with F202.4....
-
Food and Restaurant Services
In a dining area, remember to arrange tables far enough apart so a person using a wheelchair can maneuver between the tables when patrons are sitting at them....
-
(4) Adjustability: Method of Measurement
The MDE NPRM proposed that the measurement of the height of the transfer surface for both diagnostic equipment used in the supine, prone, or side-lying position and diagnostic...
-
11B-813.1 Location
Adult changing facilities shall be provided within a unisex (single-user or family) toilet room or other similar private room.
-
M305.2.8 Fittings
Transfer supports shall not rotate within their fittings when in place for transfer.