5.4.6 Transfer Support Gripping Surface Cross Section for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position. The gripping surface cross section should comply with the...
Search Results "Picnic Table"
Commonly Searched Documents
- 
    
  
  5.4.6 Transfer Support Gripping Surface Cross Section for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
  
- 
    
  
  5.7.1 Lift Compatibility Clearance in Base for Equipment Used by Patient in Supine, Prone, or Side-Lying Position
  5.7.1 Lift Compatibility Clearance in Base for Equipment Used by Patient in Supine, Prone, or Side-Lying Position. 
- 
    
  
  5.3 Transfer Sides
  5.3 Transfer Sides. 
- 
    
  
  5.4.2 Transfer Support Length for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
  5.4.2 Transfer Support Length for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position. The transfer support should be a minimum length of 15 inches positioned so that... 
- 
    
  
  5.3 Transfer Sides Recommendations
  5.3 Transfer Sides Recommendations 
- 
    
  
  5.4.5 Transfer Support Position for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
  5.4.5 Transfer Support Position for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position. The transfer gripping surface should be located within the minimum and maximum... 
- 
    
  
  5.4.9 Interruptions Along Transfer Support Gripping for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
  5.4.9 Interruptions Along Transfer Support Gripping for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position. The bottom of the transfer support shall have no... 
- 
    
  
  Recommendations on Standards for the Design of Medical Diagnostic Equipment for Adults with Disabilities, Advisory Committee Final Report
  Advancing Equal Access to Diagnostic Services: Recommendations on Standards for the Design of Medical Diagnostic Equipment for Adults with Disabilities The final report of the... 
- 
    
  
  5.7.1 Lift Compatibility Clearance in Base for M301
  5.7.1 Lift Compatibility Clearance in Base for M301 Description: For portable floor lifts to be effective, they must deploy at diagnostic equipment such that the boom of the lifts... 
- 
    
  
  M305.2.1 Location
  Transfer supports shall be located within reach of the transfer surface and shall not obstruct transfer onto or off of the surface when in position. 
- 
    
  
  M301.2.1 Adjustability
  Transfer surfaces shall be adjustable in height measured from the floor to the top of the uncompressed transfer surface and shall provide the following: A. A low transfer position... 
- 
    
  
  M301.2.2 Sunset
  The low transfer position height, Item A of M301.2.1, shall cease to have effect on [Insert date 5 years after date of publication in the Federal Register]. 
- 
    
  
  d. Unobstructed Transfer
  The MDE NPRM proposed that each transfer side provide unobstructed access to the transfer surface, with an exception to permit temporary obstructions as long as they could be... 
- 
    
  
  M301.2.1 Adjustability (Section-by-Section Analysis)
  The MDE NPRM proposed a transfer surface height range for diagnostic equipment used by patients in the supine, prone, or side-lying position of 17 inches minimum and 19 inches... 
- 
    
  
  M301.2.2 Sunset Provision (Section-by-Section Analysis)
  As discussed in Section IV.B.1.a. (Significant Changes – Transfer Surface Adjustability), this is a new provision that was added to the final rule in conjunction with the new... 
- 
    
  
  M301.4 Lift Compatibility (Section-by-Section Analysis)
  The MDE NPRM proposed to require that diagnostic equipment used by patients in the supine, prone, or side-lying position be usable with a patient lift and comply with either the... 
- 
    
  
  5.4.7 Transfer Support Gripping Surface Clearance Recommendation for M301 and M302
  5.4.7 Transfer Support Gripping Surface Clearance Recommendation for M301 and M302 Description: A clearance around the gripping surface is necessary to ensure sufficient space for... 
- 
    
  
  5.7 Lift Compatibility
  5.7 Lift Compatibility. 
- 
    
  
  5.4.7 Transfer Support Gripping Surface Clearance for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
  5.4.7 Transfer Support Gripping Surface Clearance for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position. There should be a 1½ inches minimum clearance around the... 
- 
    
  
  5.7 Lift Compatibility Recommendations
  5.7 Lift Compatibility Recommendations 
- 
    
  
  5.4.4 Transfer Support Distance From Transfer Surface for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
  5.4.4 Transfer Support Distance From Transfer Surface for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position. The transfer support should be located a maximum distance... 
- 
    
  
  (2) Adjustability: Minimum Low Transfer Height
  In the 11 years we have been selling adjustable height examination tables we do not have a single complaint on record regarding the accessibility of our 19” low height tables.... 
- 
    
  
  M305.2.5 Surface Hazards
  Transfer supports and surfaces adjacent to transfer supports shall be free of sharp or abrasive components and shall have eased edges. 